Technical guideFree to read2026

RFC 9768: More Accurate Explicit Congestion Notification (AccECN) Feedback in TCP

IETF / RFC Editor · B. Briscoe, M. Kühlewind et al.

An IETF Standards Track RFC (April 2026) that updates RFC 3168 so TCP header feedback can report more than one congestion signal per round trip, serving DCTCP, L4S and ConEx.

On this page

Overview

Explicit Congestion Notification (ECN) lets network nodes mark IP packets instead of dropping them to signal incipient congestion to endpoints. RFC 3168 specified ECN for TCP so that only one feedback signal could be returned per round-trip time (RTT). That suffices for Reno and CUBIC, which cut the congestion window by a fixed factor regardless of how many markings arrive in an RTT. DCTCP, L4S and ConEx need to know when more than one marking arrives in an RTT.

AccECN supplies this in the TCP header. Header space is scarce, so the reserved bit formerly assigned to the ECN-nonce is reused and, together with the two existing ECN flags (CWR and ECE), overloaded as a 3-bit ACE counter. A 3-bit counter wraps frequently, so the document defines safety procedures against ambiguity for the packet receiver and the data sender. The extra space is also used to feed back the IP-ECN field received during connection establishment.

Optionally, two new TCP option alternatives, never used on a SYN, carry supplementary feedback. The CE packet counter includes control packets without payload, while the CE byte counter in the option counts only marked payload bytes; when both exist the byte counter gives the more accurate information needed for L4S, DCTCP and ConEx. Feedback in bytes also protects against ACK-Division-style attacks by a receiver or middlebox that try to inflate the congestion window.

The document states that AccECN is meant to be a complete replacement for classic ECN feedback, works whether or not nodes on the path support ECN and with hosts using classic ECN, and applies to the public Internet as well as private IP networks such as data centres. It also sets compliance requirements for TCP proxies, transparent middleboxes, ACK filtering, TSO and LRO, covers interaction with SYN cookies and other TCP options, and defines tests for backward and forward compatibility.

Key points

  1. April 2026 Standards Track document that updates RFC 3168's TCP ECN feedback scheme and its negotiation; the IP-layer ECN definition is unchanged.
  2. RFC 3168 gives one feedback signal per RTT; DCTCP, L4S and ConEx must know when more than one marking arrives in an RTT.
  3. The ACE field is a 3-bit counter formed from the bit freed by the ECN-nonce plus the CWR and ECE flags; because it wraps frequently, safety procedures are defined.
  4. Two optional new TCP option alternatives (AccECN Option) carry extra feedback and are never used on a SYN.
  5. The CE byte counter counts only marked payload bytes and is more accurate than the CE packet counter in ACE; an algorithm estimates marked bytes from ACE if options are stripped.
  6. Byte-based feedback protects against ACK-Division-style attacks.
  7. Scope covers the public Internet and private IP networks such as data centres; it coexists with hosts using classic ECN.
  8. Compliance requirements are set for TCP proxies, transparent middleboxes, ACK filtering, TSO and LRO.

Using it in design

  • In data-centre networks using DCTCP or L4S, list ECN marking and host-stack AccECN support as design requirements.
  • Verify AccECN compatibility of middleboxes that alter the TCP header (proxies, normalisers, ACK filtering, offload) in commissioning tests.
  • Check whether load balancers, firewalls and offload NICs strip the ACE field or the AccECN option; stripping only reduces feedback accuracy.
  • Tune and validate switch ECN marking thresholds together with the feedback accuracy end systems provide.

Who should read it

Network architects planning congestion management, DCTCP or L4S deployment in data-centre networks, and OS, NIC and middlebox engineers.

Document contents

  1. Introduction: document roadmap, goals, terminology, recap of existing ECN feedback
  2. AccECN Protocol Overview and Rationale: capability negotiation, feedback mechanism, delayed ACKs, feedback metrics, generic reflector
  3. AccECN Protocol Specification: negotiation in the three-way handshake, backward and forward compatibility, ACE field, AccECN option, requirements for TCP proxies, middleboxes, ACK filtering, TSO and LRO
  4. Updates to RFC 3168
  5. Interaction with TCP Variants: SYN cookies, TCP experiments and common options, feedback integrity mechanisms
  6. Summary: Protocol Properties
  7. IANA, Security and Privacy Considerations
  8. Appendices: example algorithms, rationale for usage of TCP header flags

Related standards

  • RFC 9768

Publication details

Authors
B. Briscoe; M. Kühlewind; R. Scheffenegger
Publisher
IETF / RFC Editor
Year
2026
Document number
RFC 9768
Document language
English
Source type
Industry body
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

The document copyright notice identifies IETF Trust Legal Provisions (BCP 78). Full-text redistribution and adaptation conditions were not separately audited; this deliverable is metadata and original summary only.

Citation

B. Briscoe; M. Kühlewind; R. Scheffenegger (2026). RFC 9768: More Accurate Explicit Congestion Notification (AccECN) Feedback in TCP. IETF / RFC Editor. RFC 9768. https://doi.org/10.17487/RFC9768

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Data centre layout in SoSo CAD

Design rack layout, power supplies and cooling zones within the same project.

Racks and infrastructure equipment on a SoSo CAD floor plan

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.