RFC 8365: A Network Virtualization Overlay Solution Using Ethernet VPN (EVPN)

IETF / RFC Editor · A. Sajassi (Ed.), J. Drake (Ed.) et al.

An IETF Standards Track RFC (March 2018) defining BGP EVPN as the control plane for data-centre network virtualisation overlays using VXLAN, NVGRE or MPLS over GRE, including VNI-to-EVI mapping and local-bias split horizon for multihoming.

On this page

Overview

RFC 8365 specifies how EVPN can be used as a network virtualization overlay (NVO) solution and explores the effect of different IP tunnel encapsulations on the EVPN control plane and procedures. Encapsulations analysed are VXLAN, NVGRE and MPLS over GRE; the specification also applies to GENEVE, though some incremental work is covered separately. EVPN features listed include control-plane distribution with BGP, control-plane MAC (and IP) learning, route reflectors to reduce BGP full mesh, BGP auto-discovery of PEs, All-Active multihoming, fast convergence, BGP route filtering, VM mobility and route targets.

For VXLAN and NVGRE, two options map virtual identifiers (VNI, VSID) to an EVI. In Option 1 a single broadcast domain maps to one EVI (the VLAN-based service); an RD and RT are needed per VNI, with the advantage that BGP RT constraint can limit propagation to interested NVEs and the disadvantage of provisioning overhead unless RD and RT are auto-derived from the VNI. In Option 2 multiple subnets of a tenant map to one EVI (the VLAN-aware bundle service); no per-VNI RD/RT is needed, but routes may be imported by NVEs not interested in a VNI.

For a multihomed NVE (in a ToR switch), the central point on split horizon is that an ESI label does this in MPLS, but VXLAN and NVGRE carry no ESI label, so local bias is recommended. Each NVE tracks the IP addresses of NVEs with which it shares multihomed ESs and filters a multi-destination frame, by the source IP in the tunnel header, on local interfaces attached to those shared ESs. This requires the ingress NVE to replicate locally to all directly attached Ethernet segments regardless of DF election state. Fast convergence, mass withdrawal, aliasing and backup path, DF election and unknown-unicast designation are also covered.

The document also covers multicast support (IMET route and PMSI Tunnel attribute) and data-centre interconnect (DCI) using gateways (GWs) or ASBRs. With inter-AS option B, mass withdrawal falls back from per-ES to per-EVI mode. Service with multiple encapsulations and the cases of a single-homed NVE in a hypervisor versus a multihomed NVE in a ToR are in separate sections. Together with VXLAN it forms the basis of the common EVPN-VXLAN fabric design.

Key points

  1. March 2018 Standards Track RFC defining EVPN as an NVO control plane and analysing VXLAN, NVGRE and MPLS over GRE; also applicable to GENEVE.
  2. Two VNI-to-EVI mapping options: one broadcast domain per EVI (VLAN-based) or many per EVI (VLAN-aware bundle).
  3. Option 1 needs an RD and RT per VNI and RT constraint limits propagation to interested NVEs; Option 2 needs no per-VNI RD/RT but uninterested NVEs may import routes.
  4. VXLAN and NVGRE carry no ESI label, so 'local bias' split horizon is used for multihoming.
  5. Under local bias the ingress NVE replicates locally to all directly attached Ethernet segments regardless of DF state.
  6. Multihoming features: ES auto-discovery, fast convergence and mass withdrawal, split horizon, aliasing and backup path, DF election.
  7. Multicast discovery uses the IMET route and the PMSI Tunnel attribute.
  8. In inter-AS option B DCI, mass withdrawal falls back from per-ES to per-EVI mode.

Using it in design

  • In a VXLAN fabric, record the VNI-to-EVI mapping option (VLAN-based or VLAN-aware bundle) and whether RD and RT are auto-derived from the VNI.
  • For multihomed server attachment on ToR switches, verify local-bias support and the ingress NVE's local replication behaviour during device selection.
  • When choosing between GW and ASBR DCI, include in convergence expectations that mass withdrawal falls to per-EVI mode in the ASBR model.
  • Decide the BUM approach (multicast tunnel via IMET or ingress replication) and its underlay requirement.
  • Document the procedural differences between a single-homed NVE in a hypervisor and a multihomed NVE in a ToR in operations material.

Who should read it

Network architects designing VXLAN-EVPN data-centre fabrics and engineers evaluating multihoming and DCI options.

Document contents

  1. Introduction
  2. Requirements Notation and Conventions
  3. Terminology
  4. EVPN Features
  5. Encapsulation Options for EVPN Overlays: VXLAN/NVGRE encapsulation (virtual identifier scope, VNI-to-EVI mapping, constructing EVPN BGP routes), MPLS over GRE
  6. EVPN with Multiple Data-Plane Encapsulations
  7. Single-Homing NVEs: NVE Residing in Hypervisor
  8. Multihoming NVEs: NVE Residing in ToR Switch (multihoming features, impact on BGP routes and procedures)
  9. Support for Multicast
  10. Data-Center Interconnections (DCIs): DCI Using GWs, DCI Using ASBRs
  11. Security and IANA Considerations

Related standards

  • RFC 7432
  • RFC 7348

Publication details

Authors
A. Sajassi (Ed.); J. Drake (Ed.); N. Bitar; R. Shekhar; J. Uttaro; W. Henderickx
Publisher
IETF / RFC Editor
Year
2018
Document number
RFC 8365
Document language
English
Source type
Expert / community
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

IETF Trust copyright under the Trust Legal Provisions; link and cite.

Citation

A. Sajassi (Ed.); J. Drake (Ed.); N. Bitar; R. Shekhar; J. Uttaro; W. Henderickx (2018). RFC 8365: A Network Virtualization Overlay Solution Using Ethernet VPN (EVPN). IETF / RFC Editor. RFC 8365. https://doi.org/10.17487/RFC8365

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Data centre layout in SoSo CAD

Design rack layout, power supplies and cooling zones within the same project.

Racks and infrastructure equipment on a SoSo CAD floor plan

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.