RFC 8014: An Architecture for Data-Center Network Virtualization over Layer 3 (NVO3)
IETF / RFC Editor · D. Black, J. Hudson et al.
A 2016 informational IETF RFC that defines the NVO3 reference architecture for tenant virtual networks over Layer 3 underlays: NVEs, NVAs, gateways and the NVE-NVA protocol.
On this page
Overview
RFC 8014 presents the architectural framework for carrying tenant virtual networks over a Layer 3 infrastructure by encapsulation in data centre networks. The aim is to give tenants L2 or L3 virtual network service isolated from the physical network. The document recommends no particular encapsulation; it defines the common model and terms on which solutions such as VXLAN sit.
At the centre of the architecture is the Network Virtualization Edge (NVE). It keeps a table per virtual network, encapsulates traffic from tenant systems and decapsulates it at the far end. An NVE can be co-located with a server hypervisor or moved into the switch (split-NVE). Virtual network identifiers and virtual access points (VAPs) are mapped at this point. Multihoming, multicast and unicast replication options are also covered.
In the control plane, the Network Virtualization Authority (NVA) knows which tenant systems sit behind which NVE and distributes that mapping. The document examines NVE-NVA interaction models, how an NVA learns from VM orchestration, and how several NVAs interwork (federated NVAs). Three protocol needs are listed: hypervisor-NVE, NVE-NVA and NVA-NVA.
Tenant system types include bare metal servers, network service appliances and gateways; an L2 gateway bridges, while an L3 gateway handles IP packets only. Distributed inter-VN gateways and ARP/ND handling are covered as well. The document is an architectural framework; it contains no protocol detail, configuration or performance data.
Key points
- NVO3 builds virtual networks over an L3 underlay by encapsulation; the document does not mandate a specific encapsulation format.
- An NVE keeps per-virtual-network state: attached tenant systems, inner-address to remote-NVE mapping for unicast, and mappings for multicast.
- An NVE can sit with the hypervisor or in the switch (split-NVE); split-NVE needs a hypervisor-NVE protocol.
- Three protocol needs: hypervisor-NVE, NVE-NVA and NVA-NVA.
- The NVA knows tenant system locations and distributes them to NVEs; federated NVAs let several authorities peer.
- Tenant multicast can ride IP multicast or, if the underlay does not support it, unicast replication.
- An L2 gateway bridges and an L3 gateway forwards IP packets only; gateways can be virtual or hardware.
- Bare metal servers and overlay-aware network service appliances are treated as distinct tenant system types.
Using it in design
- Choose the NVE location (server or leaf switch) early in overlay design; with bare metal servers, plan switch-based NVEs or gateways.
- Decide, from multicast needs, between IP multicast and unicast replication in the underlay and calculate the effect on leaf-spine capacity.
- Define explicitly the source of virtual network mapping information (an NVA, the orchestration system or EVPN).
- Set gateway location and redundancy for traffic leaving the overlay and passing between virtual networks.
Who should read it
Data centre network architects, cloud and virtualisation platform designers, and engineers evaluating overlay network protocols.
Document contents
- Introduction
- Terminology
- Background
- Network Virtualization Edge (NVE)
- Tenant System Types
- NVE-NVE Interaction
- Network Virtualization Authority (NVA)
- NVE-NVA Protocol
- Federated NVAs
- Control-Plane Components
Related standards
- RFC 7364
- RFC 7365
Publication details
- Authors
- D. Black; J. Hudson; L. Kreeger; M. Lasserre; T. Narten
- Publisher
- IETF / RFC Editor
- Year
- 2016
- Document number
- RFC 8014
- Document language
- English
- Source type
- Expert / community
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
IETF Trust copyright under the Trust Legal Provisions; link and cite.
Citation
D. Black; J. Hudson; L. Kreeger; M. Lasserre; T. Narten (2016). RFC 8014: An Architecture for Data-Center Network Virtualization over Layer 3 (NVO3). IETF / RFC Editor. RFC 8014. https://doi.org/10.17487/RFC8014
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.