Technical guideFree to read2017

RFC 8238: Data Center Benchmarking Terminology

IETF / RFC Editor · L. Avramov, J. Rapp

An August 2017 IETF Informational RFC defining terms for benchmarking data-centre switches and routers (latency, jitter, physical-layer calibration, line rate, buffering, incast, goodput); it is a prerequisite for the RFC 8239 test methodology.

On this page

Overview

The document notes that data-centre traffic is not uniform: depending on applications it may be mostly east-west or north-south, bursty, many-to-one, many-to-many or one-to-many; flows may be small and latency sensitive or large and throughput sensitive, with UDP and TCP mixed. Older benchmarks such as RFC 1242, 2544, 2889 and 3918 focus on theoretical maximum throughput, forwarding rate and latency, and do not represent real traffic patterns. RFC 8238 fills that gap with new terminology for data-centre switches and routers.

In the latency definition, the time a frame takes to transit the device under test (DUT) can be measured with one of four event combinations (FILO, FIFO, LILO, LIFO). Switch latency must be measured with FILO because it includes the switch latency, the frame latency and serialisation delay, and covers both store-and-forward and cut-through behaviour. LIFO can yield negative latency on cut-through devices for larger packets and must not be used to compare two DUTs. Jitter is defined as packet delay variation (PDV), reported as a Max-Min range or the 99th percentile.

Line-rate measurement accounts for Ethernet clock tolerance: standards limit transmit clock variation to at most +/- 100 PPM from the centre frequency, and if a test set runs +1 PPM faster than the DUT in a sustained line-rate test latency gradually grows and packets drop once buffers fill. At about 99 percent link occupancy, low latency and no loss are achieved. The buffering section defines buffer size, port buffer size, maximum port and DUT buffer size, always with MTU and CoS/DSCP value, plus burst, microburst and microburst intensity (a percentage from 1 to 100).

The document also defines incast (many-to-one flows) and data-centre goodput. Physical-layer calibration requires listing and reporting the test equipment, line cards, transceivers, cable type and length, and software versions with the results. The document gives no view on ideal buffer size, explains only how to measure it, and notes that a larger buffer is not necessarily better because of bufferbloat.

Key points

  1. August 2017 Informational RFC; a prerequisite for the RFC 8239 test methodology.
  2. Switch latency must be measured with FILO events, and the event combination used is reported in all cases.
  3. LIFO can give negative latency on cut-through devices and must not be used to compare two different DUTs.
  4. Jitter is packet delay variation (PDV), reported as a Max-Min range or the 99th percentile.
  5. Physical-layer calibration lists traffic generator, line cards, transceivers, cable type and length, and software name and version.
  6. Ethernet standards allow at most +/- 100 PPM transmit clock variation; certification instruments are typically +/- 30 PPM or better.
  7. About 99 percent link occupancy gives low latency and no loss; true 100 percent line rate can fill buffers through clock mismatch.
  8. Buffer size is expressed with MTU and CoS or DSCP value (example: 18 MB for 1518-byte frames); microburst intensity ranges from 1 to 100 percent.

Using it in design

  • In switch acceptance-test specifications, require latency to be measured with FILO and the event combination to be reported.
  • When comparing vendor latency and buffer data, check that MTU, CoS and DSCP conditions are identical.
  • In line-rate tests, adjust the test set's clock offset or use about 99 percent occupancy; otherwise clock mismatch creates artificial loss.
  • Request the calibration list (cable type and length, transceivers, software versions) with test results.
  • For AI and storage clusters, state incast and microburst behaviour in switch selection using the buffer terms (maximum port buffer, maximum DUT buffer).

Who should read it

Network engineers selecting data-centre switches and routers and writing acceptance tests, plus test labs and vendors.

Document contents

  1. Introduction: requirements language, definition format
  2. Latency: definition, discussion, measurement units
  3. Jitter
  4. Calibration of the Physical Layer
  5. Line Rate
  6. Buffering: buffer, incast
  7. Application Throughput: Data Center Goodput
  8. Security and IANA Considerations

Related standards

  • RFC 8238

Publication details

Authors
L. Avramov; J. Rapp
Publisher
IETF / RFC Editor
Year
2017
Document number
RFC 8238
Document language
English
Source type
Industry body
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

The document copyright notice identifies IETF Trust Legal Provisions (BCP 78). Full-text redistribution and adaptation conditions were not separately audited; this deliverable is metadata and original summary only.

Citation

L. Avramov; J. Rapp (2017). RFC 8238: Data Center Benchmarking Terminology. IETF / RFC Editor. RFC 8238. https://doi.org/10.17487/RFC8238

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.