RFC 8239: Data Center Benchmarking Methodology
IETF / RFC Editor · L. Avramov, J. Rapp
A 2017 informational IETF RFC that defines repeatable line-rate, buffer, microburst, head-of-line blocking and incast tests for data centre switches, with relative standard deviation required below 10%.
On this page
Overview
RFC 8239 is a methodology document for benchmarking physical data centre network devices (the device under test, DUT). Classic RFC 2544 and RFC 2889 tests measure theoretical throughput and latency but do not reflect the bursty, many-to-one traffic patterns found in data centres. The document closes that gap through congestion scenarios. Terminology from RFC 8238 is a normative prerequisite.
Every test section follows the same three headings: objective, methodology and reporting format. The line-rate test requires the traffic generator to send at no more than 99.98% of nominal line rate and to report minimum, average and maximum throughput, latency and jitter for packet sizes from 64 to 9216 bytes. When a generator cannot connect to all ports, a snake connection is used, though latency and jitter are then disregarded.
The buffer test creates congestion by sending known-size packets from several ingress ports to one egress port; the number of packets sent up to the point where maximum latency stops growing gives the buffer size. The microburst test increases the packets per burst until loss begins. The head-of-line blocking test uses two groups of four ports, and the incast test mixes TCP goodput with UDP microbursts on one egress port.
The document adds no security or IANA requirements. Repeatability is stressed throughout, and buffer testing is noted as historically the least reliable measurement. The methodology assumes a DUT with at least nine ports. It defines no acceptance thresholds or selection criteria, only measurement and reporting rules.
Key points
- In the line-rate test the sending rate must not exceed 99.98% of nominal line rate, with no PPM adjustment.
- Throughput, latency and jitter are reported across packet sizes from 64 to 9216 bytes; the common order is 64, 128, 256, 512, 1024, 1518, 4096, 8000 and 9216 bytes.
- For repeatability the number of iterations must be reported and relative standard deviation should stay below 10%.
- Buffer size is the number of packets sent from the oversubscribing port up to the maximum-latency inflection point, multiplied by packet size; 1% oversubscription is recommended.
- The microburst test runs at 100% intensity from at least two ingress ports to one egress port (2 to 1) and stops at the first non-zero loss.
- The head-of-line blocking test starts with two groups of four ports and shifts port numbers by one in the second iteration; it measures loss on the egress port that is not oversubscribed.
- The incast test mixes stateful (TCP goodput) and stateless (UDP microburst) traffic on one egress port.
- When a generator cannot reach every port, the snake test covers line rate but excludes latency and jitter.
Using it in design
- Add a requirement to leaf and spine switch specifications that vendors supply line-rate, buffer and microburst results in RFC 8239 format.
- Where many-to-one traffic is expected (storage, AI collective communication), make buffer and incast results a primary comparison criterion between models.
- In the commissioning test plan, define snake and full-mesh tests separately and require iteration count and deviation in the report.
- When comparing vendor data, confirm that packet size and sending rate conditions are identical.
Who should read it
Data centre network architects, switch procurement and specification teams, and commissioning test engineers.
Document contents
- Introduction
- Line-Rate Testing
- Buffering Testing
- Microburst Testing
- Head-of-Line Blocking
- Incast Stateful and Stateless Traffic
- Security Considerations
- IANA Considerations
- References
Related standards
- RFC 8239
Publication details
- Authors
- L. Avramov; J. Rapp
- Publisher
- IETF / RFC Editor
- Year
- 2017
- Document number
- RFC 8239
- Document language
- English
- Source type
- Industry body
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
The document copyright notice identifies IETF Trust Legal Provisions (BCP 78). Full-text redistribution and adaptation conditions were not separately audited; this deliverable is metadata and original summary only.
Citation
L. Avramov; J. Rapp (2017). RFC 8239: Data Center Benchmarking Methodology. IETF / RFC Editor. RFC 8239. https://doi.org/10.17487/RFC8239
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.