StandardPaid2021

Information technology - Data centre facilities and infrastructures - Part 1: General concepts

ISO/IEC · ISO/IEC JTC 1

The international standard at the base of the ISO/IEC 22237 series, defining terminology, reference models and a classification system built on availability, security and energy efficiency.

This document is sold by ISO/IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.

On this page

Overview

ISO/IEC 22237-1:2021 is the international counterpart of EN 50600-1 and sets the general principles on which the other parts of the ISO/IEC 22237 series rely. The first edition, published in October 2021, runs to 29 pages and replaces the 2018 Technical Specification ISO/IEC TS 22237-1. It is not a design specification in itself but the common language and framework of the series; topics such as power, cooling, cabling and security are detailed in other parts.

At its centre is a classification system. The system rests on availability, security and energy efficiency over the planned lifetime. This lets the data centre owner state the target class that fits the business requirements, and lets designers decide component-level redundancy and protection against that target. The standard also defines common terminology, parameters and reference models covering functional elements and how they are accommodated.

Another contribution is the idea that class selection should not be arbitrary. To make the classification applicable, the standard details the issues that a business risk and operating cost analysis must address. The chosen class is thereby grounded in the organisation's real risk appetite and cost realities. This turns the class into a documented decision taken at the start of the design. The limits of scope are also clear: selection of IT and network equipment and quantitative multi-site availability analysis fall outside the series. Related standards include EN 50600-1, ISO/IEC 22237-3, ISO/IEC 22237-4 and TIA-942. The full text is a paid standard; this summary relies only on the publisher's public catalogue abstract and product metadata.

Key points

  1. International counterpart of EN 50600-1; sets the general principles of the ISO/IEC 22237 series.
  2. Defines a classification system based on availability, security and energy efficiency over the planned lifetime.
  3. Provides common terminology, parameters and reference models (functional elements and their accommodation).
  4. Details the issues a business risk and operating cost analysis must address to apply the classification.
  5. Selection of IT/network equipment and quantitative multi-site availability analysis are outside the scope.
  6. Edition 1 was published 2021-10-05 (29 pages) and replaces ISO/IEC TS 22237-1:2018.
  7. Related standards: EN 50600-1, ISO/IEC 22237-3, ISO/IEC 22237-4 and TIA-942.

Using it in design

  • Assess ISO/IEC 22237 and EN 50600 when establishing the project’s applicable standards.
  • Map the availability class (1-4) to default redundancy rules for power and cooling.
  • Instead of asking novices to pick a class, start with a guided risk and cost questionnaire that recommends one.
  • Record security and energy-efficiency targets alongside availability as part of the classification.

Who should read it

Designers, consultants and investment decision makers who set the classification target of a data centre.

Related standards

  • EN 50600-1
  • ISO/IEC 22237-3
  • ISO/IEC 22237-4
  • TIA-942

Publication details

Authors
ISO/IEC JTC 1
Publisher
ISO/IEC
Year
2021
Document number
ISO/IEC 22237-1:2021
Document language
English
Source type
Standard
Access
Paid; available from the publisher
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.

Citation

ISO/IEC JTC 1 (2021). Information technology - Data centre facilities and infrastructures - Part 1: General concepts. ISO/IEC. ISO/IEC 22237-1:2021. https://webstore.iec.ch/en/publication/71475

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.