Congestion Control Mechanism Based on Backpressure Feedback in Data Center Networks

Future Internet (MDPI) · Wei Li, Mengzhen Ren et al.

A 2024 Future Internet paper proposes BFCC, switch-to-switch backpressure feedback that resolves congestion in a one-hop RTT; simulation shows 1.2 to 2 times faster average flow completion times than other mechanisms.

On this page

Overview

Rapid growth in data-centre traffic causes congestion. Most proposed end-to-end congestion controls respond within one round-trip time (RTT). This paper proposes congestion control based on backpressure feedback (BFCC), designed for switch-to-switch operation to resolve congestion within a one-hop RTT.

The approach uses a programmable data plane to monitor network congestion in real time, identify the flows that are actually congested, and apply targeted flow control through backpressure feedback. Feasibility was validated on BMV2, a P4-based programmable virtual switch. Simulation results show BFCC improves average flow completion times by 1.2 to 2 times compared with other end-to-end mechanisms.

Key points

  1. BFCC is designed for switch-to-switch congestion control and aims to resolve congestion within a one-hop RTT.
  2. End-to-end congestion controls react within one RTT; BFCC aims to shorten that reaction time.
  3. A programmable data plane monitors congestion in real time and identifies the flows causing it.
  4. Targeted flow control is applied through backpressure feedback.
  5. Feasibility was validated on the P4 BMV2 virtual switch; performance findings are simulation results.
  6. In simulation, average flow completion time is 1.2 to 2 times faster than other mechanisms.

Using it in design

  • In congestion-management strategy, include switch-level feedback in network design comparisons instead of relying only on end-to-end mechanisms.
  • Add programmable data-plane requirements (P4 support, telemetry) to switch selection criteria when such approaches are considered.
  • Do not treat simulation results as acceptance criteria for a production network; plan pilot validation on real hardware.
  • Add flow completion time to acceptance tests as a network performance metric.

Who should read it

Data-centre network architects, congestion-control researchers and designers using programmable switches.

Publication details

Authors
Wei Li; Mengzhen Ren; Yazhi Liu; Chenyu Li; Hui Qian; Zhenyou Zhang
Publisher
Future Internet (MDPI)
Year
2024
Document number
16(4), 131
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Article-specific publisher landing page opened on 2026-11-16; copyright statement explicitly links CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Preserve attribution and check separate third-party credit lines before reusing figures. Round 2 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Wei Li; Mengzhen Ren; Yazhi Liu; Chenyu Li; Hui Qian; Zhenyou Zhang (2024). Congestion Control Mechanism Based on Backpressure Feedback in Data Center Networks. Future Internet (MDPI). 16(4), 131. https://doi.org/10.3390/fi16040131

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.