Inter-Data Center RDMA: Challenges, Status, and Future Directions
Future Internet (MDPI) · Xiaoying Huang, Jingwei Wang
A 2025 review in Future Internet on extending RDMA across data centres, covering congestion control and load balancing; the authors present it as the first review article focused on inter-DC RDMA.
On this page
Overview
RDMA is widely deployed in data centres because of its high bandwidth, low latency and low overhead. As applications relying on inter-DC interconnection multiply, the demand for running RDMA across data centres is rising. Intra-DC RDMA has been studied extensively, while research on inter-DC RDMA is scarce but growing.
The article identifies the specific challenges of inter-DC RDMA deployment, such as congestion control and load balancing, then surveys recent progress in making RDMA applicable in these environments and presents future research directions. The authors position it as the first review focused on the topic.
Key points
- RDMA is widespread in data centres for its high bandwidth, low latency and low overhead.
- Applications that rely on inter-DC interconnection increase demand for RDMA across data centres.
- Intra-DC RDMA is well studied; inter-DC RDMA research is relatively scarce but growing.
- The main challenges named are congestion control and load balancing.
- The article surveys recent progress and presents future research opportunities.
Using it in design
- For inter-DC RDMA planning, treat congestion control and load balancing as separate requirements early in the WAN design.
- Assume settings that work for intra-DC RDMA do not carry over unchanged to long-distance links and plan separate validation tests.
- Document the load-balancing strategy for inter-DC links that use multiple paths.
- Use the open research directions as the rationale for pilots and fallback plans for immature solutions.
Who should read it
Network architects designing multi-site AI and HPC networks and researchers on inter-data-centre connectivity.
Publication details
- Authors
- Xiaoying Huang; Jingwei Wang
- Publisher
- Future Internet (MDPI)
- Year
- 2025
- Document number
- 17(6), 242
- Document language
- English
- Source type
- Scientific
- Access
- Free to read
- Licence
- CC BY 4.0: share with attribution
Original licence note
Article-specific publisher landing page opened on 2026-11-16; copyright statement explicitly links CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Preserve attribution and check separate third-party credit lines before reusing figures. Round 2 ingestion retains bibliographic metadata only; no local full text is redistributed.
Citation
Xiaoying Huang; Jingwei Wang (2025). Inter-Data Center RDMA: Challenges, Status, and Future Directions. Future Internet (MDPI). 17(6), 242. https://doi.org/10.3390/fi17060242
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.