GSA Commissioning Guide (September 2020)

U.S. General Services Administration (Public Buildings Service), 2020, Guide or technical publication

The U.S. General Services Administration's framework for Total Building Commissioning on federal projects, replacing the 2005 edition. Data center designers can use it as a process template for scopi…

Guide or technical publication

2020

PDF

TM 5-693 Uninterruptible Power Supply System Selection, Installation, and Maintenance for Command, Control, Communications, Computer, Intelligence, Surveillance, and Reconnaissance (C4ISR) Facilities (31 May 2002)

U.S. Army Corps of Engineers (Headquarters, Department of the Army), 2002, Guide or technical publication

A U.S. Army technical manual on static and rotary UPS systems for mission-critical command-and-control facilities. It gives sound fundamentals on operating principles, configurations, sizing, batteri…

Guide or technical publication

2002

PDF

TM 5-698-1 Reliability/Availability of Electrical & Mechanical Systems for Command, Control, Communications, Computer, Intelligence, Surveillance and Reconnaissance (C4ISR) Facilities (19 January 2007)

Headquarters, Department of the Army (U.S. Army Corps of Engineers), 2007, Guide or technical publication

An Army manual on reliability, availability and maintainability (RAM) analysis of the electrical and mechanical systems of mission-critical facilities. It gives the definitions, redundancy rules…

Guide or technical publication

2007

PDF

TM 5-698-3, Reliability Primer for Command, Control, Communications, Computer, Intelligence, Surveillance, and Reconnaissance (C4ISR) Facilities (14 October 2005)

U.S. Army Corps of Engineers (Headquarters, Department of the Army technical manual), 2005, Guide or technical publication

An Army introduction to reliability engineering: probability foundations, reliability prediction, series, parallel and k-of-N block diagrams, designing for reliability, production and operational…

Guide or technical publication

2005

PDF

TM 5-698-4 Failure Modes, Effects and Criticality Analyses (FMECA) for Command, Control, Communications, Computer, Intelligence, Surveillance, and Reconnaissance (C4ISR) Facilities (29 September 2006)

U.S. Army Corps of Engineers (Headquarters, Department of the Army), 2006, Guide or technical publication

An Army manual on performing FMEA and FMECA for critical facility systems such as power, generators and HVAC. It includes ready-made worksheets, severity and occurrence ranking tables, quantitative…

Guide or technical publication

2006

PDF