ENERGY STAR Computer Servers SERT V2.0.8 Clarification Memo (September 25, 2024)

U.S. Environmental Protection Agency (ENERGY STAR) · Ryan Fogle

A one-page EPA memo announcing that SPEC SERT version 2.0.8 is the version to use for ENERGY STAR server certification. It tells anyone storing or comparing server efficiency scores which tool version is current.

U.S. public domain — U.S. Government work; free to reuse

On this page

Overview

The memo is a letter dated 25 September 2024 from the US Environmental Protection Agency (EPA) to ENERGY STAR Computer Server partners, certification bodies and recognised laboratories. EPA reports that SPEC's Server Efficiency Rating Tool (SERT) has been updated and that, for certification, servers should be tested with SERT 2.0.8 from now on.

The update is described as minor, and the results it produces are stated to be comparable with those of earlier versions. Two changes are listed: added support for regulatory certification of NVIDIA Grace, AMD Instinct MI300A and Microsoft Pioneer platforms, and the PTDaemon 1.11.0 interface together with support for newer LTS Java versions.

There is no retroactive effect: results already submitted through the certification process using a SERT version that EPA accepted earlier are unaffected. The memo is posted on the Computer Servers Version 4.0 specification development website, and it gives separate contact points for SERT 2.0.8 certification questions and for other server questions.

Key points

  1. From the date of the memo, certification testing should use SERT 2.0.8.
  2. Results submitted with previously accepted SERT versions remain valid.
  3. The update is minor and its results are comparable with earlier versions.
  4. Regulatory certification support is added for NVIDIA Grace, AMD Instinct MI300A and Microsoft Pioneer.
  5. The PTDaemon 1.11.0 interface and newer LTS Java versions are supported.
  6. The memo is posted on the Version 4.0 specification development site.

Using it in design

  • Store the SERT version alongside every imported server efficiency score so comparisons between catalogue entries stay traceable.
  • Do not recompute or invalidate scores obtained with earlier accepted SERT versions; treat them as comparable per the memo.
  • Flag accelerator-class platforms such as Grace and MI300A as eligible candidates in ENERGY STAR-aware server selection.

Monthly newsletter · free

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.

SoSo CAD

Compare the cost of design decisions

Evaluate equipment costs, energy expenses and total cost of ownership (TCO) using your inputs and assumptions in SoSo CAD.

Request a demo
CAPEX and TCO estimates in the SoSo CAD cost workspace

Who should read it

Engineers who catalogue server efficiency data or select ENERGY STAR certified hardware, and test-laboratory staff.

Document contents

  1. Memo body: use of SERT 2.0.8
  2. Change list (new platform support, PTDaemon, Java)
  3. Validity of previously submitted results
  4. Contacts and certification enquiries

Related standards

  • SPEC SERT 2.0.8
  • ENERGY STAR Computer Servers V4.0

Read the document

energystar-servers-sert-2-0-8-memo.pdf

PDF · 0.1 MB · English

U.S. public domain — U.S. Government work; free to reuse

The document is provided unaltered because its licence permits redistribution.

Publication details

Authors
Ryan Fogle
Publisher
U.S. Environmental Protection Agency (ENERGY STAR)
Year
2024
Document language
English
Source type
Government / public
Access
Open licence — downloadable
Licence
U.S. public domain — U.S. Government work; free to reuse
Licence evidence
www.copyright.gov
Original licence note

Memo on EPA Office of Air and Radiation letterhead signed by the EPA ENERGY STAR manager; U.S. government work (17 U.S.C. 105).

Citation

Ryan Fogle (2024). ENERGY STAR Computer Servers SERT V2.0.8 Clarification Memo (September 25, 2024). U.S. Environmental Protection Agency (ENERGY STAR). https://www.energystar.gov/sites/default/files/2024-09/ENERGY%20STAR%20Computer%20Servers%20SERT%20V2.0.8%20Clarification%20Memo.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.