NFPA 110, Standard for Emergency and Standby Power Systems
NFPA · National Fire Protection Association
The standard setting performance requirements for emergency and standby power systems that supply an alternate source when normal power fails; the usual reference for generator plant in US data centre projects.
On this page
Overview
NFPA 110 is a performance standard for emergency and standby power systems that provide an alternate source when normal power fails. The systems it covers include power sources, transfer equipment, controls, supervisory equipment and accessory equipment. In data centres, particularly US projects, it is the usual reference for the performance, testing and maintenance of generator plant. This scope treats standby power as a system running from source to load rather than as a single machine.
The current edition is 2025; the next edition is expected in 2028 and is being prepared in the Annual 2027 revision cycle. According to NFPA's development page, the topics under revision include inspection, testing and maintenance. The record here rests only on NFPA's public standard development page. That inspection, testing and maintenance are among the topics shows that the operating process is a significant part of the standard. The revision calendar helps users plan edition changes in advance.
The full text was not read here, so details such as class, type and level definitions and test intervals must be taken from the original. The standard addresses the performance of the system as a whole, not individual generator products. On data centre projects, the document serves as a basis for accounting for operating and commissioning requirements at design stage.
Key points
- Title: Standard for Emergency and Standby Power Systems.
- The current edition is 2025; the next edition is 2028.
- Covers performance requirements for systems that provide an alternate source when normal power fails.
- Systems include power sources, transfer equipment, controls, supervisory and accessory equipment.
- The next edition is in the Annual 2027 revision cycle; topics include inspection, testing and maintenance.
- In data centres it is the reference for generator plant performance, testing and maintenance in US projects.
Using it in design
- In the generator module, capture the EPSS class (fuel run time), type (start time) and level on the generator object and size fuel storage to the class.
- Generate the acceptance and periodic test schedule (load bank, transfer tests) for commissioning.
- Cite it as the reference standard for generator performance and maintenance requirements on US projects.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Review your power design in SoSo CAD
Inspect supply paths, equipment loads and UPS failure scenarios in one model.
Request a demo
Who should read it
Electrical engineers who design, commission and operate generator and standby power systems for data centres.
Related standards
- NFPA 111
- NFPA 70
- ISO 8528
Publication details
- Authors
- National Fire Protection Association
- Publisher
- NFPA
- Year
- 2025
- Document number
- NFPA 110
- Document language
- English
- Source type
- Standard
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
NFPA codes are copyrighted; free read-only access requires an NFPA account, purchase otherwise. Record uses only the public NFPA development page.
Citation
National Fire Protection Association (2025). NFPA 110, Standard for Emergency and Standby Power Systems. NFPA. NFPA 110. https://www.nfpa.org/codes-and-standards/nfpa-110-standard-development/110
Events on this subject
Browse the events calendarAll content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.