Water Reuse Action Plan 2.0: Summer Update, January-May 2026
Original title Water Reuse Action Plan 2.0: Summer Update, January–May 2026
U.S. Environmental Protection Agency
EPA's WRAP 2.0 summer update lists the 27 new actions launched in April 2026, including data-centre cooling reuse actions 2.21, 3.10 and 8.12.
On this page
Overview
EPA relaunched the Water Reuse Action Plan (WRAP 2.0) in April 2026. This update gives an overview of the 27 new actions announced at the launch. The starting point is that AI and data-centre growth, expanding manufacturing and rising energy production are changing water needs quickly, and reuse is presented as a strategy to extend national water resources.
The document groups actions by theme: reuse for resurgent domestic industry (food and beverage, automotive, a PFAS working group, a map of recycled water for industry), the US technology revolution, and energy dominance. The data-centre actions sit under the technology theme and describe planned work; they do not contain completed site performance or final design standards.
The data-centre actions are: Action 2.21 (Part 1) seeks solutions to regulatory hurdles for recycled water in data-centre cooling; Part 2 creates an AI Center of Excellence to examine how and when data centres source water and sets out four principles for responsible water use. Action 3.10, led by EPA, compiles best practices so states can readily permit recycled water for industrial and data-centre cooling. Action 8.12 hosts a data-centre forum for water and wastewater utilities.
Seven WRAP actions were completed in the last quarter, among them standards and methods for air-conditioning condensate reuse in large buildings (Action 4.5). The update will be published quarterly and calls for new commitments.
Key points
- WRAP 2.0 was relaunched in April 2026; the update summarises 27 new actions.
- Action 2.21 (Part 1): AWS, Brown and Caldwell, Loudoun Water, EPA, Veralto and WEF will identify and propose solutions to regulatory hurdles for recycled water in data-centre cooling.
- Action 2.21 (Part 2): an AI Center of Excellence examines how and when data centres source water; four principles for responsible water use have been outlined.
- Action 3.10: EPA compiles best practices so states can readily permit recycled water for data-centre cooling.
- Action 8.12: WRF hosts a data-centre forum for water and wastewater utilities.
- Action 5.13: WateReuse maps utilities with usable recycled water for industry.
- Seven actions were completed last quarter; Action 4.5 addressed air-conditioning condensate reuse.
- The document describes planned work, not completed site performance or final design standards.
Using it in design
- Evaluate recycled water for data-centre cooling at siting with the local utility and identify permitting hurdles early.
- If reclaimed water is used, size towers and the cooling loop for its quality and treatment needs.
- Consider air-conditioning condensate as a supplementary make-up source for towers.
- Track state permitting developments (Action 3.10) in the project permitting schedule.
Who should read it
Designers developing data-centre water strategy, water utilities, and permitting and regulatory specialists.
Document contents
- Message from the Assistant Administrator
- WRAP 2.0 Actions
- Reuse for Resurgent Domestic Industry
- Reuse for the U.S. Technology Revolution
- Reuse for Energy Dominance
- Completed Actions
- Recent WRAP Outputs and Activities
Publication details
- Authors
- U.S. Environmental Protection Agency
- Publisher
- U.S. Environmental Protection Agency
- Year
- 2026
- Document number
- WRAP2.0 Summer Update2026
- Document language
- English
- Source type
- Government / public
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Publisher public source inspected. No document-specific commercial redistribution permission established; metadata and original short summaries only.
Citation
U.S. Environmental Protection Agency (2026). Water Reuse Action Plan 2.0: Summer Update, January–May 2026. U.S. Environmental Protection Agency. WRAP2.0 Summer Update2026. https://www.epa.gov/system/files/documents/2026-07/wrap-quarterly-update-july-2026.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.