Water vs. PG25 in Data Center Liquid Cooling: The Trade-Off Inside the Server Loop

Saint-Gobain ICS · Ned Burnett

A Saint-Gobain ICS article weighing treated water against inhibited PG25 on thermal properties, material compatibility, handling conditions and maintenance programme; FWS and TCS fluids need not be the same.

On this page

Overview

The article examines the choice between treated water and inhibited PG25 together with thermal properties, material compatibility, handling conditions and maintenance programme. It does not assume that FWS and TCS fluids must be the same.

It distinguishes pure water from chemically conditioned water for operation. Cold plate comparisons are described as first-order estimates at fixed geometry, not experimental results.

Key points

  1. Treated water and inhibited PG25 are compared on thermal properties, material compatibility, handling conditions and maintenance programme.
  2. FWS and TCS fluids are not assumed to be the same.
  3. Pure water and chemically conditioned water for operation are treated separately.
  4. Cold plate comparisons are first-order estimates at fixed geometry, not experimental results.

Using it in design

  • Select the fluid separately for the TCS and FWS loops; do not assume one fluid.
  • Evaluate water versus PG25 together with thermal properties, material compatibility, handling conditions and maintenance programme.
  • Use the cold plate comparison as a first-order estimate and test for the real geometry.

Who should read it

Mechanical designers and operations teams selecting TCS loop fluids.

Publication details

Authors
Ned Burnett
Publisher
Saint-Gobain ICS
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Ned Burnett Water vs. PG25 in Data Center Liquid Cooling: The Trade-Off Inside the Server Loop. Saint-Gobain ICS. https://www.ics.saint-gobain.com/resources/blog/water-vs-pg25-data-center-liquid-cooling-trade-inside-server-loop

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.