How Pressure Transducers and Other Control Products Enhance Data Center Reliability
Barksdale · Barksdale Control Products
A February 2026 Barksdale article that maps which pressure, temperature, level, flow and speed sensors suit which application across liquid cooling, backup power and building utility systems in a data centre.
On this page
Overview
The article describes how pressure, temperature, level and flow sensors and switches are positioned across three system groups in a data centre: liquid cooling and support infrastructure, power and backup infrastructure, and building utility and maintenance systems. It stresses that even minor fluctuations in cooling, power or fluid management can jeopardise operations.
The liquid cooling group lists chilled water systems, liquid cooling loops, cooling towers and pumps, and water treatment systems. For each it pairs the pressure and temperature transducer (BoT), electronic pressure and temperature switches (BPS, BTS), flow switch (BFS), differential pressure electronic switch (BDS), level switches and magnetic level indicator (BNA).
For power and backup, it recommends pressure transducers and switches, temperature switches and Dynalco speed switches on diesel and natural gas generator fuel systems, fuel cells and gas turbines. Building utilities cover HVAC, fire suppression, condensate reservoirs, CRAC/CRAH units and pump and boiler systems.
It is vendor content in the form of a product map; it gives no numeric accuracy, range or failure-rate figures and leaves detail to datasheets.
Key points
- Three system groups are covered: liquid cooling and support, power and backup, building utility and maintenance.
- Chilled water systems are paired with the BoT transducer and BPS and BTS electronic switches.
- Liquid cooling loops, towers and pumps are paired with BoT and the BFS flow switch.
- Water treatment uses BoT, the BDS differential pressure switch, level switches and the BNA magnetic level indicator.
- Generator fuel systems use BoT and Dynalco speed switches; gas turbines add temperature switches.
- CRAC/CRAH units use pressure and temperature transducers; condensate reservoirs use level switches and BNA.
- Fire suppression uses BoT, pressure switches and the BFS flow switch.
Using it in design
- In a liquid cooling instrumentation list, define pressure, temperature and flow measurement points per loop.
- Add differential pressure switching on filters and exchangers to monitor clogging.
- Plan level switches plus a level indicator as redundant measurement on water treatment and condensate tanks.
- Wire generator fuel and cooling subsystem pressure, temperature and speed sensors into the BMS alarm list.
Who should read it
Mechanical, electrical and controls engineers specifying monitoring and instrumentation for cooling, backup power and utility systems.
Document contents
- Solutions for Key Data Center Systems
- Liquid Cooling and Support Infrastructure
- Power & Backup Infrastructure
- Building Utility & Maintenance Systems
- Datasheets
Publication details
- Authors
- Barksdale Control Products
- Publisher
- Barksdale
- Year
- 2026
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Barksdale Control Products (2026). How Pressure Transducers and Other Control Products Enhance Data Center Reliability. Barksdale. https://www.barksdale.com/blog/how-pressure-transducers-and-other-control-products-enhance-data-center-reliability
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.