Liquid cooling filtration in data centers: application brief
Original title Liquid cooling filtration in data centers: Application Brief
Eaton
A short Eaton application brief that maps filtration duties across the CWS, FWS and TCS loops and separates the cooling-tower strainer from the cold-plate protection filters; the 25 micrometre figure is a manufacturer recommendation for the HAYFLOW QDC element.
On this page
Overview
The brief maps the different filtration duties in the CWS, FWS and TCS loops of a liquid-cooled facility on a diagram. The cooling-tower strainer and the filters used to protect cold plates are shown separately.
The diagram separates the facility and technology water loops at the CDU heat exchanger, so each loop's contamination risk and filter duty can be assessed on its own.
The 25 micrometre value is a manufacturer recommendation for the Eaton HAYFLOW QDC filter element.
Key points
- The brief maps filtration duties across the CWS, FWS and TCS loops.
- The tower-water strainer and the cold-plate protection filters are shown separately.
- The diagram separates facility and technology water loops at the CDU heat exchanger.
- The 25 micrometre value is a manufacturer recommendation for the HAYFLOW QDC element.
Using it in design
- Define the filtration duty for each water loop separately: a tower strainer is not a cold-plate protection filter.
- Compare the filter rating at the cold-plate inlet with the cold-plate manufacturer's requirement.
- Treat the CDU heat exchanger as the loop boundary and plan filter locations on both sides.
- Verify manufacturer recommendations such as 25 micrometres against your own equipment specification.
Who should read it
Mechanical engineers designing water loops and filtration for liquid cooling.
Publication details
- Authors
- Eaton
- Publisher
- Eaton
- Year
- 2026
- Document number
- Application Brief, March 2026
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Eaton (2026). Liquid cooling filtration in data centers: Application Brief. Eaton. Application Brief, March 2026. https://www.eaton.com/content/dam/eaton/products/filtration-solutions/filter-systems-and-strainers/filters-and-strainers/manual-pipeline-strainers/brochures/eaton-liquid-cooling-filtration-in-data-centers-application-brief-en.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.