Accounting carbon emissions from electricity generation: a review and comparison of emission factor-based methods
Applied Energy (Elsevier BV) · Marina Bertolini, Pierdomenico Duttilo et al.
The paper reviews emission-factor methods for estimating direct CO2 emissions from electricity generation, organised by the IPCC 2006 Tier 1/2/3 framework, and compares six methods on hourly ENTSO-E generation data for the seven Italian market zones over 2016-2023.
CC BY 4.0 — share with attribution
On this page
Overview
Accurate estimation of greenhouse gas emissions is essential to meet carbon-neutrality targets, particularly through calculating direct CO2 emissions from electricity generation. The basic emission formula is E = activity data × emission factor; Tier 1 uses IPCC default factors, Tier 2 country-specific factors and Tier 3 plant/technology-specific data. Fuel emission factors used (IPCC default): fossil coal 94.60 tCO2/TJ, natural gas 56.10, fossil oil 77.7, derived gas 107.07; the Italian (ISPRA) derived-gas factor is 163.36 tCO2/TJ.
The methods produce very different totals: three simple formulations underestimate emissions by about 73% against the best estimates. North zone 2022: Method 5 (Tier 2, ISPRA factors, with CO2/C molecular-weight ratio) gave the highest estimate, about 57.5 Mt CO2; Method 4 was about 2% lower, Method 6 (Tier 3-type Carbon Monitor adjustment) almost 11% lower, and Methods 1-3 about 73% lower. Average yearly emission factor (AEF) for the North zone by Method 5 rose from 0.1627 tCO2/MWh in 2016 to 0.4709 in 2022, then fell to 0.3936 in 2023.
For 2018 in Northern Italy, the plant-level Tier 3 approach of Beltrami et al. gave 36,625,956 tCO2 and an AEF of 0.2840 tCO2/MWh, differing from Method 5 by 8% in emissions and 9% in AEF. 2023 AEF for the island zones depends strongly on the factor source: Sicily 0.5939 (Method 4) vs 0.4937 tCO2/MWh (Method 5), and Sardinia 0.9984 vs 0.7265, because of the derived-gas factor (IPCC 0.39 vs ISPRA 0.59 tCO2/MWh). Adding the carbon oxidation fraction (Method 3) made little difference, and a Tier 3 label did not guarantee higher accuracy: the Tier 3-type Method 6 underestimated relative to Tier 1/2 Methods 4-5.
The finding is that accuracy does not rank cleanly by tier, and country- or zone-specific factors matter most where fuels such as derived gases are significant; applied in the correct context, Tier 1 methods can also perform well. The paper focuses on generation-side (production-based) average emission factors and does not address marginal factors.
Key points
- The basic emission formula is E = activity data × emission factor; Tier 1 uses IPCC defaults, Tier 2 country-specific factors, Tier 3 plant/technology-specific data.
- Fuel emission factors (IPCC default): fossil coal 94.60 tCO2/TJ, natural gas 56.10, fossil oil 77.7, derived gas 107.07; the Italian (ISPRA) derived-gas factor is 163.36 tCO2/TJ.
- North zone 2022: Method 5 gave the highest estimate (about 57.5 Mt CO2); Method 4 about 2% lower, Method 6 almost 11% lower, Methods 1-3 about 73% lower.
- AEF for the North zone by Method 5 rose from 0.1627 tCO2/MWh in 2016 to 0.4709 in 2022, then fell to 0.3936 in 2023.
- For 2018 in Northern Italy, the plant-level Tier 3 approach gave 36,625,956 tCO2 and an AEF of 0.2840 tCO2/MWh, differing from Method 5 by 8% in emissions and 9% in AEF.
- 2023 AEF for the island zones depends strongly on the factor source: Sicily 0.5939 (Method 4) vs 0.4937 (Method 5), Sardinia 0.9984 vs 0.7265 tCO2/MWh; the cause is the derived-gas factor (IPCC 0.39 vs ISPRA 0.59 tCO2/MWh).
- Adding the carbon oxidation fraction (Method 3) made little difference; a Tier 3 label did not guarantee higher accuracy.
Using it in design
- In data-centre carbon accounting, state the method (Tier 1, 2, 3) and factor source (IPCC or national) when choosing a grid emission factor; simple methods can underestimate generation emissions by about 73%.
- Use country- or zone-specific factors where derived gas and similar fuels have a significant share; in the island zones factor choice changed AEF by 20-37%.
- Note in the report that a production-based average factor does not represent marginal impact and that marginal approaches are needed for load-shifting or siting decisions.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Compare the cost of design decisions
Evaluate equipment costs, energy expenses and total cost of ownership (TCO) using your inputs and assumptions in SoSo CAD.
Request a demo
Who should read it
Sustainability analysts choosing electricity emission-factor methods and doing data-centre Scope 2 accounting.
Document contents
- 1 Introduction
- 2 Review of emission-factor-based methods under the IPCC Tier 1/2/3 framework
- 3 Comparison of methods: six methods, Italian market zones, hourly ENTSO-E data 2016-2023
- 4 Results
- 5 Discussion
- 6 Conclusions
Related standards
- GHG Protocol Corporate Standard
- IPCC 2006 Guidelines for National Greenhouse Gas Inventories
Read the document
electricity-emission-factor-methods-review-2025.pdf
CC BY 4.0 — share with attribution
The document is provided unaltered because its licence permits redistribution.
Publication details
- Authors
- Marina Bertolini; Pierdomenico Duttilo; Francesco Lisi
- Publisher
- Applied Energy (Elsevier BV)
- Year
- 2025
- Document number
- arXiv:2411.13663
- Volume
- 392
- Pages
- 125992
- Document language
- English
- Source type
- Scientific
- Access
- Open licence — downloadable
- Licence
- CC BY 4.0 — share with attribution
- Licence evidence
- arxiv.org
Original licence note
arXiv OAI-PMH record for 2411.13663 gives license http://creativecommons.org/licenses/by/4.0/. Downloaded file is the arXiv author version of the published (CC-BY) journal article; url points to the journal DOI.
Citation
Marina Bertolini; Pierdomenico Duttilo; Francesco Lisi (2025). Accounting carbon emissions from electricity generation: a review and comparison of emission factor-based methods. Applied Energy (Elsevier BV). arXiv:2411.13663. 392, 125992. https://doi.org/10.1016/j.apenergy.2025.125992
Events on this subject
Browse the events calendarAll content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.