Data Center Liquid-Cooling Systems with Polypropylene Pipe
Aquatherm
Aquatherm's whitepaper argues that heat-fused polypropylene (PP) pipe offers leak-free joints, up to 75% less weight and a 50-year rated life against steel, copper, PVC and PEX in data-centre liquid cooling.
On this page
Overview
The whitepaper explains that heat is one of the biggest risks to data centres, that air cooling needs raised floors and extensive HVAC, and that liquid cooling becomes more suitable as density rises. It states that water removes heat 3,467 times more efficiently than air, and that the usual objection to liquid cooling is fear of pipe failure and leaks.
Pipe material options are compared. Steel, copper, PVC and PEX rely on foreign substances such as glue, solder or mechanical joints, which can eventually fail. For steel and copper it lists condensation, corrosion, fumes and particles from welding and soldering, fire-alarm risk from open flames, weight and cost. PP, in contrast, is joined by heat fusion, so the joint is the same material as the pipe with no chemical or mechanical element.
Properties claimed for PP: no rust, scale or erosion, a 50-year expected life, an R-value of roughly 1 giving limited natural insulation (the manufacturer should still be consulted on condensation), about 75% lower linear expansion for the multi-layer fibre-composite type, up to 70% less weight than steel, a size range of 20-630 mm OD, no hot-work permit because no open flame is used, and recyclability. It is a manufacturer whitepaper and these claims are not backed by independent test data.
Key points
- Water is stated to remove heat 3,467 times more efficiently than air.
- Depending on size and wall thickness, PP pipe weighs up to 70% less than carbon steel pipe (elsewhere in the text, up to 75% less than metal).
- Heat fusion makes pipe and fitting a single piece without glue, solder or mechanical joints.
- Expected life is 50 years; natural R-value is roughly 1.
- In the multi-layer fibre-composite (MF) type, linear expansion and contraction fall by about 75% against other plastics.
- Connections can be ready in under an hour; there is no open flame or VOC, so hot-work permits and fire-system triggering are not a concern.
- Pipe sizes run from 20 mm to 630 mm OD.
- Some manufacturers offer a 10-year insurance policy or warranty.
Using it in design
- For chilled-water and liquid cooling lines, weigh material choice together with joint method (weld, solder, glue, heat fusion), chemical compatibility and operating temperature and pressure limits.
- Do not rely on PP's limited natural insulation for condensation; resolve it with a manufacturer calculation and, where needed, insulation and drip trays.
- If PP replaces steel or copper, reflect the lower pipe weight in hanger and support design.
- Include the no-hot-work joining method in the commissioning schedule and fire detection coordination for work inside the data hall.
- Confirm the manufacturer's classification and life rating for design temperature and pressure; the document does not give these values.
Who should read it
Mechanical designers and contractors selecting pipe material for data-centre chilled-water and liquid cooling.
Document contents
- Air cooling vs. liquid cooling
- Benefits and drawbacks to piping-system options
- PP systems: a strong alternative
- Conclusion
- Pipe material comparison table (PP, copper, steel)
Publication details
- Authors
- Aquatherm
- Publisher
- Aquatherm
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Aquatherm Data Center Liquid-Cooling Systems with Polypropylene Pipe. Aquatherm. https://aquatherm.com/wp-content/uploads/2019/04/FINAL-APPROVED-Data-Center-Liquid-Cooling_whitepaper_FINAL_2.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.