CEJN Data Center Thermal Control: Quick Coupling Solutions for High-Performing Liquid Cooling Systems
Original title Connecting the data center industry: Quick coupling solutions for high-performing liquid cooling systems
CEJN · CEJN AB
CEJN's 2024 brochure presents OCP-interchangeable BMQC (±5 mm radial, ±2.7° angular tolerance), UQD/UQDB and CDU LQC quick couplings with 10-12 bar working pressure ratings.
On this page
Overview
The brochure states that cloud, machine learning and AI applications push cooling capacity needs and that quick couplings are the core of liquid cooling systems. CEJN cites experience in quick coupling technology since 1955 and describes a role as main developer in solutions created within the Open Compute Project (OCP). An interview section defines OCP's aim as interchangeable couplings from different makers.
The product family is: BMQC (compact blind-mate, ±5 mm radial and ±2.7° angular misalignment tolerance, interchangeable with OCP BMQC), UQDB (blind-mate, ±1 mm radial tolerance, interchangeable with OCP UQDB), UQD (hot-swappable under pressure, safe connection up to 5 bar differential pressure, interchangeable with OCP UQD, double O-ring seal, colour coded) and LQC (high-flow, screw-to-connect locking for CDUs, interchangeable with OCP LQC). Seals are EPDM, UL-IEC 62368-1 approved, with ISO 11926 threads for BMQC and UQDB and BSP (G) and NPT threads for LQC.
The product data table gives LQC a 19 mm nominal flow diameter (G 1 inch or NPT 1 inch), 12 bar (174 psi) maximum working pressure and 48 bar (696 psi) minimum burst pressure, and UQD02 (3.2 mm), UQD04 (6.4 mm), UQD06 (9.5 mm) and UQD08 (12.7 mm) sizes with 10 bar (145 psi) working and 40 bar (580 psi) burst pressure. It is a product brochure; flow coefficient or pressure drop curves are not included here.
Key points
- BMQC: ±5 mm radial and ±2.7° angular misalignment tolerance; interchangeable with OCP BMQC.
- UQDB: ±1 mm radial tolerance, blind-mate; interchangeable with OCP UQDB.
- UQD: connect and disconnect under pressure, safe connection up to 5 bar differential pressure, double O-ring seal.
- LQC: high-flow screw-to-connect for CDUs, 19 mm nominal flow diameter, 12 bar working pressure, 48 bar minimum burst pressure.
- UQD02, UQD04, UQD06 and UQD08 nominal flow diameters 3.2, 6.4, 9.5 and 12.7 mm; 10 bar working, 40 bar minimum burst pressure.
- EPDM seals; UL-IEC 62368-1 approved; ISO 11926 threads for BMQC and UQDB.
- Colour-coding options prevent cross connection.
- CEJN is a main developer in OCP coupling solutions and has made quick couplings since 1955.
Using it in design
- In blind-mate rack design, compare BMQC's ±5 mm radial and ±2.7° angular tolerance with rack and server placement tolerances.
- For in-server quick connects, choose size (3.2-12.7 mm) by nominal flow diameter against branch flow.
- Consider 19 mm LQC with screw-to-connect locking for high-flow CDU lines.
- Separate supply and return lines with colour-coded couplings.
- Compare working pressure (10 or 12 bar) with site and rack pressure class and check burst margin.
Who should read it
Engineers and procurement teams selecting hydraulic couplings for liquid-cooled racks, CDUs and servers.
Document contents
- Quick couplings: the core of liquid cooling systems
- OCP solutions and customised solutions
- Focus case: CEJN and the Open Compute Project
- Product features: BMQC, UQDB, UQD, LQC
- Product data
Publication details
- Authors
- CEJN AB
- Publisher
- CEJN
- Year
- 2024
- Document number
- 09 0010 802_en
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
CEJN AB (2024). Connecting the data center industry: Quick coupling solutions for high-performing liquid cooling systems. CEJN. 09 0010 802_en. https://www.cejn.com/globalassets/documents/brochures/data-center/09-0010-802_dc-brochure_web.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.