Technical guideFree to read2026

Veri Merkezi Çözümleri (Data Centre Solutions, EAE Elektrik)

Original title Veri Merkezi Çözümleri

EAE Elektrik

A coordinated Turkish-language manufacturer catalogue from EAE Elektrik covering busway power distribution, racks, containment, cable trays, modular hangers and seismic supports for data centres.

On this page

Overview

The catalogue (Catalogue 17, Rev. 14, 06/10/2026) approaches data-centre infrastructure through four challenges: energy efficiency, availability, scalability and security. For efficiency it proposes treating heat sources in the IT power infrastructure under an energy optimisation programme, reducing power losses, and separating hot and cold air through correct airflow management and aisle containment. For availability it refers to the Uptime Institute Tier classifications and EN 50600.

The product groups start with busway systems: E-LINE KX is a compact busbar from 400 A to 6300 A (aluminium or copper conductors, plug-in outlets every 60 cm, IP55 and IP65, seismic compatibility, outlet boxes up to 630 A plug-in and up to 1200 A bolted), and E-LINE KD is a 160 A to 1000 A data-centre rack busbar system. These are followed by KabinPLUS rack cabinets (42U and 47U, up to 1500 kg load capacity) and hot and cold aisle containment, E-LINE wire cable trays, PanelMaster type-tested low-voltage panels (up to 6800 A, Icw 120 kA/1 s, internal arc 65 kA/0.3 s, seismic withstand up to 0.66 g) and lighting systems.

The hanger and support section presents E-Line BR, E-Line A-A and seismic support systems for cable trays, cable ladders and seismic support of electrical and mechanical equipment. The overview lists wall-type, ceiling-type, threaded-rod (single and double rod), heavy-duty RSP carrier, BINRAK channel and auxiliary profile, pipe clamps and seismic or rigid support arrangements. The seismic hanger section describes supporting busways, cable carriers and mechanical services under horizontal earthquake forces in a controlled way; they are hot-dip galvanised (TS EN ISO 1461).

The document is a manufacturer catalogue: it shows the interfaces of the products with electrical and mechanical services and the seismic support approach, but contains no seismic design calculation or project-specific load tables. Under data-centre security it mentions lockable busway tap-off boxes, seismic hangers and high-fire-resistance busway and rack systems.

Key points

  1. Catalogue 17, Rev. 14, 06/10/2026; Turkish, EAE Elektrik.
  2. E-LINE KX: 400-6300 A compact busbar; plug-in outlets every 60 cm; IP55/IP65; plug-in boxes up to 630 A, bolted up to 1200 A.
  3. E-LINE KD: 160-1000 A data-centre rack busway system.
  4. KabinPLUS cabinets: 42U and 47U, up to 1500 kg load capacity; hot and cold aisle containment systems.
  5. PanelMaster panel: up to 6800 A, 690 V AC, Icw 120 kA/1 s, internal arc 65 kA/0.3 s, seismic withstand up to 0.66 g, up to IP55.
  6. Hanger systems: wall, ceiling, threaded rod, heavy-duty RSP, BINRAK, pipe clamps; seismic and rigid support solutions.
  7. Seismic hangers support busways, cable carriers and mechanical services against horizontal earthquake forces; hot-dip galvanised (TS EN ISO 1461).
  8. Uptime Institute Tier classifications and EN 50600 are cited as the availability framework.

Using it in design

  • Design the hanging points of busways and cable carriers together with the seismic hanger scope; horizontal earthquake forces need a project-specific calculation, the catalogue shows only product groups.
  • Document the placement and load sharing of electrical and mechanical services (busway, cable tray, pipe) on a shared carrier in an interface table.
  • In E-LINE KX and KD selection, assess the current range (400-6300 A and 160-1000 A) and outlet box capacities (630 A plug-in, 1200 A bolted) separately for white space and main distribution.
  • In rack selection match the 1500 kg load capacity and containment type (hot or cold aisle) with the airflow design.
  • In panel selection compare the internal arc and Icw values with the site short-circuit current.

Who should read it

Designers coordinating data-centre electrical, mechanical and structural interfaces, and engineers writing specifications.

Document contents

  1. Data centre solutions and company profile
  2. Challenges: energy efficiency, availability, scalability, security
  3. Busway power distribution systems (E-LINE KD, KX, CCR)
  4. Rack cabinets and aisle containment (KabinPLUS)
  5. MFIX modular support systems and hanger systems
  6. Seismic hanger systems
  7. Cable management systems (E-LINE TLS)
  8. Low-voltage type-tested panel systems

Related standards

  • TS EN ISO 1461

Publication details

Authors
EAE Elektrik
Publisher
EAE Elektrik
Year
2026
Document number
Katalog 17 - Tr.; Rev.14; 06/10/2026
Document language
Turkish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Public publisher source inspected on 2026-11-16. No document-specific redistribution permission established. Edition and date printed on PDF p.40. Source differs from the previously accepted individual EAE busway installation manuals.

Citation

EAE Elektrik (2026). Veri Merkezi Çözümleri. EAE Elektrik. Katalog 17 - Tr.; Rev.14; 06/10/2026. https://www.eae.com.tr/storage/kataloglar/Data%20Center%20_TR.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.