Technical guideFree to read2026

Fracarro Networking Brochure 2026: Rack Cabinets and Accessories

Fracarro

Fracarro's 2026 networking brochure lists 19-inch floor-standing cabinets in 42U, 36U and 24U and wall-mount cabinets in 12U and 9U with model and size tables; accessory codes are separate from cabinet codes.

On this page

Overview

The brochure presents Fracarro's networking solutions: passive copper and fibre components, active devices and rack cabinets. The portfolio is designed for deploying broadband telecommunications networks in commercial, hospitality and residential facilities, with particular expertise in GPON solutions. Fracarro offers network designers design support, logical network diagrams, bills of materials (BOM) and technical data sheets, and installers remote support, IP plan definition and training.

The rack section presents 19-inch floor-standing and wall-mounted cabinets for telecommunications, IT and audio/video installations. Floor-standing models offer high load capacity and modular structure, wall-mounted ones are compact and easy to install, and both come pre-assembled. Floor-standing cabinets: 42U at 800x1000x2000 (RK42U810S, mesh front door), 800x800x2000 (RK42U88S) and 600x800x2000 mm (RK42U68P, tempered glass front door); 36U at 600x800x1735 and 600x600x1735 mm; 24U at 600x800x1200 and 600x600x1200 mm. The 42U models have four mounting rails and the 36U and 24U models two.

Wall-mounted cabinets are 12U (600x450x615 mm, RK12U64PW) and 9U (600x450x485 mm, RK9U64PW), with fixed rails and tempered glass front doors. The accessory table gives, under separate codes, vertical rails for 42U cabinets, 1U cable management panels (slotted, solid, brush) and adjustable or fixed shelves (350, 800 and 1000 mm depth).

Other sections cover Ethernet cables (Cat 5E, 6, 6A; 305 m and 500 m reels), RJ45 plugs, keystone jacks, a 24-port 1U patch panel, fibre optic components, SFP modules and GPON active devices. The document is a manufacturer brochure; accessory codes should be kept separate from cabinet identifiers.

Key points

  1. Floor-standing cabinets: 42U (three sizes), 36U (two sizes) and 24U (two sizes); sizes in mm are 800x1000x2000, 800x800x2000, 600x800x2000, 600x800x1735, 600x600x1735, 600x800x1200 and 600x600x1200.
  2. The 42U models have four mounting rails; the 36U and 24U models have two.
  3. On the 42U models RK42U810S and RK42U88S the front door is mesh, and the others have tempered glass.
  4. Wall-mount 12U (600x450x615 mm) and 9U (600x450x485 mm) models are given in a separate table; they have fixed rails and tempered glass doors.
  5. Each model has its own product code (for example RK42U810S, code 287676); accessories are listed under separate codes.
  6. Accessories: vertical rails for 42U, 1U cable management panels, and shelves of 350, 800 and 1000 mm depth.
  7. Cabinets are delivered pre-assembled.
  8. The 1U patch panel takes up to 24 RJ45 keystone ports and has a stainless steel rear panel.
  9. Ethernet cables are offered on 305 m (indoor) and 500 m (outdoor) reels.

Using it in design

  • In cabinet selection, record height (42U, 36U, 24U, 12U, 9U) and width x depth with the product code; each model has its own code.
  • Prepare a bill of materials that keeps accessory codes (rails, cable management, shelves) apart from cabinet codes.
  • Match cabinet depth and shelf depth (350, 800, 1000 mm) to equipment depth.
  • Use the network and wall-mount cabinets for small distribution points, and check the load capacity of a different cabinet family for high power-density racks.
  • Reflect in the equipment mounting plan that 42U models have four rails and the others two.

Who should read it

Designers and installers specifying cabinets and accessories for small and mid-size network rooms.

Document contents

  1. Networking solutions and Fracarro networking services
  2. Copper passive components (Ethernet cables, RJ45 plugs, keystone jacks, keystone box, patch panel)
  3. Rack cabinets and accessories (floor-standing and wall-mounted)
  4. Fibre optics (passive fibre components, cables, SFP)
  5. Active devices (GPON, access point, controllers)

Publication details

Authors
Fracarro
Publisher
Fracarro
Year
2026
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Fracarro (2026). Fracarro Networking Brochure 2026: Rack Cabinets and Accessories. Fracarro. https://fracarro.com/wp-content/uploads/pdf-repository/english/Brochure_Networking_EN_2026.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.