Technical guideFree to readYear not stated

Why Water Quality Matters for Data Center Cooling Performance

Graver Technologies

A Graver Technologies article on how corrosion, biofilm, galvanic attack and scaling degrade liquid-cooled data center performance, recommending a water quality baseline before commissioning.

On this page

Overview

The manufacturer article opens by noting that air cooling has reached its limits under rising rack densities and processor heat loads, while liquid cooling allows tighter racks and energy savings. It stresses that water interacts chemically with every surface it touches, including pipes, heat exchangers, pumps and server components, so poor water quality erodes the infrastructure from within.

Four main risks are listed: corrosion driven by dissolved oxygen, aggressive pH and ionic contaminants; bacteria and biofilm in open-loop or cooling tower systems (insulating effect, lower flow, microbiologically influenced corrosion); galvanic corrosion where dissimilar metals share a loop; and calcium and magnesium carbonate scale, where even a thin layer on heat transfer surfaces lowers efficiency.

The protection layers described are filtration (cartridge filters, self-cleaning strainers), ion-exchange softening, corrosion and scale inhibitors with biocide dosing, dispersants and pH buffers, and reverse osmosis plus deionization where ultra-pure water is needed. The text argues that clean water carries heat more efficiently and that regular treatment cuts maintenance cost and the chance of unplanned downtime.

The best-practice section applies equally to direct liquid cooling (DLC), rear-door heat exchangers and cooling tower chilled-water plants: set a water quality baseline before commissioning, define target parameters, filter at all system boundaries and sample at least monthly. The article is manufacturer content and gives no numeric limits; its later sections present the company's high-flow cartridge and membrane filters.

Key points

  1. Four main risks: corrosion, biological growth, galvanic corrosion, and scaling and fouling.
  2. Corrosion generates particulates that circulate and cause secondary damage and blockages.
  3. Biofilm insulates surfaces, reduces flow and can cause microbiologically influenced corrosion.
  4. Even a thin scale layer noticeably reduces heat transfer and makes the system work harder for the same cooling.
  5. Before commissioning, source water chemistry, loop materials and the temperature and pressure range should be assessed together to set the baseline.
  6. Sampling should be at least monthly, and more frequent at startup or after changes in load, chemistry or flow.
  7. Filtration should cover all system boundaries as strainers, depth filters and fine filtration.
  8. Membrane filtration may be needed where DLC or high-density racks tighten particulate specifications.

Using it in design

  • Write target water quality parameters (pH, conductivity, hardness, particulates, biological load) into the design basis and operating specification.
  • List loop materials (copper, aluminium, steel, stainless) and check galvanic compatibility; build the inhibitor programme around any dissimilar metals.
  • Place suitably rated filters and strainers ahead of heat exchangers, cold plates and CDU inlets, and add change-out interval and differential-pressure alarms to the maintenance plan.
  • Take a baseline water analysis before commissioning and keep it as the reference for monthly samples.
  • Provide biocide dosing and sampling points in the piping design for open-loop or cooling tower systems.

Who should read it

Mechanical engineers designing liquid-cooling water loops, and commissioning and operations teams of liquid-cooled data centers.

Document contents

  1. The Rise of the Liquid-Cooled Data Center
  2. Understanding the Risks of Poor-Quality Water
  3. Why Water Treatment for Data Centers Is Non-Negotiable
  4. Water Quality, Energy Efficiency and Operating Costs
  5. Best Practices for a Data Center Water Cooling System
  6. Filtration and Water Treatment Solutions

Publication details

Authors
Graver Technologies
Publisher
Graver Technologies
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Graver Technologies Why Water Quality Matters for Data Center Cooling Performance. Graver Technologies. https://www.gravertech.com/blog/why-water-quality-matters-for-data-center-cooling-performance

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.