Next Generation Data Center Thermal Management: Liquid Cooling

Parker Hannifin

Parker Hannifin's 2021 technical paper (Bulletin 3800) on selecting quick couplings, valves and seal materials in liquid cooling circuits, covering CDU, rack manifold and server connections.

On this page

Overview

The paper is a dated manufacturer technical paper focused on selection of quick couplings, valves and sealing materials in liquid cooling circuits. Fluid loss during service and pressure drop are assessed together across CDU, cabinet manifold and server connections.

A flat-face closing mechanism and seal materials suited to the application are treated as parts of connection selection.

Key points

  1. Topic: selection of quick couplings, valves and seal materials in liquid cooling circuits.
  2. CDU, cabinet manifold and server connections are assessed.
  3. Fluid loss during service and pressure drop are considered together.
  4. A flat-face closing mechanism is part of connection selection.
  5. Seal materials suited to the application are part of connection selection.

Using it in design

  • Select connections at CDU, manifold and server by assessing fluid loss during service together with pressure drop.
  • Compare flat-face closing connections as a separate option in the specification.
  • Match seal material to the fluid and operating conditions and verify compatibility.

Who should read it

Mechanical designers selecting liquid cooling couplings and valves.

Publication details

Authors
Parker Hannifin
Publisher
Parker Hannifin
Year
2021
Document number
Bulletin 3800 – LQD /USA 10/21 QCD
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Parker Hannifin (2021). Next Generation Data Center Thermal Management: Liquid Cooling. Parker Hannifin. Bulletin 3800 – LQD /USA 10/21 QCD. https://www.parker.com/content/dam/Parker-com/Literature/Quick-Coupling/Parker_Liquid_Cooling_whitepaper_Final.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.