STAUFF Solutions for Data Center Infrastructure: Fluid Conveyance, Connection and Fastening Technology
STAUFF
A STAUFF product overview (October 2026) listing DIN 3015 clamps, filters, valves and connectors for five data centre sub-systems: liquid cooling distribution, immersion cooling, fire suppression, power and data cable management and emergency power.
On this page
Overview
The document is a manufacturer product overview showing which data centre sub-systems use its pipe, hose and cable fastening, fluid connection and filtration products. The five sub-systems covered are liquid cooling distribution systems, liquid immersion cooling systems, fire suppression systems, electrical power and data cable management and emergency and independent power supply.
For liquid cooling distribution it offers DIN 3015 block-type clamps (flame-retardant polymer rated UL 94 V-0, or aluminium), strut-mounted cushion clamps, round-steel U-bolts and pressure testing equipment. The standard series covers diameters from 3.2 mm (1/8 inch) to 102 mm (4 inch); the intermediate series goes to 219 mm (NPS 8) and the heavy series to 406 mm (NPS 16).
For immersion cooling it lists single or double aluminium inline spin-on filters up to 14 bar (174 PSI), spin-on cartridges with water-absorbing properties and two-stage bypass (kidney loop) filter systems with a motor-pump unit. Fire suppression adds ball valves, ISO 8434-1 / DIN 2353 metric tube connectors (4 to 42 mm outer diameter) and a tube forming system.
The document contains no numeric performance test or field data; it summarises product families, materials (stainless steel 303/304/316, zinc/nickel-coated carbon steel) and standards compliance. It asks readers to consult the manufacturer on fluid compatibility.
Key points
- Five sub-systems: liquid cooling distribution, immersion cooling, fire suppression, cable management, emergency power.
- DIN 3015 block-type clamps: flame-retardant polymer (UL 94 V-0) or non-combustible aluminium.
- Standard series diameters run from 3.2 mm (1/8 inch) to 102 mm (4 inch); intermediate to 219 mm and heavy to 406 mm.
- Metal hardware is stainless steel 303/304/316 or zinc/nickel-coated carbon steel.
- Strut-mounted cushion clamps cover 6.4 mm (1/4 inch) to 168 mm (6 inch).
- Round-steel U-bolts to DIN 3570 span 25 to 521 mm (NPS 20).
- Spin-on filters are inline up to 14 bar (174 PSI); water-absorbing cartridges are available.
- Metric tube connectors to ISO 8434-1 / DIN 2353 cover 4 to 42 mm outer diameter.
Using it in design
- In pipe and hose support design, select the DIN 3015 series (standard, intermediate, heavy) by pipe diameter and specify V-0 rating or aluminium bodies in fire areas.
- Provide permanently installed zero-spill pressure test points in the piping design for commissioning and acceptance tests.
- For an immersion circuit, compare inline spin-on and bypass filter options against flow and fluid.
- Balance metal hardware material (stainless or zinc/nickel-coated carbon steel) against environment and cost.
- Specify a suitable clamp system on cable routes to keep power and data lines separated.
Who should read it
Mechanical and electrical designers and contractors specifying pipe, cable and fluid hardware for data centres.
Document contents
- STAUFF Components for Data Center Infrastructure
- Thermal Management | Liquid Cooling Distribution Systems
- Thermal Management | Liquid Immersion Cooling Systems
- Fire Suppression Systems
- Electrical Power and Data Cable Management Systems
- Emergency and Independent Power Supply Systems
Publication details
- Authors
- STAUFF
- Publisher
- STAUFF
- Year
- 2026
- Document number
- Product Overview, Version 10/2026
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document