Liquid cooling for processors: How couplings from STAUFF's QRC-FR series protect high-performance IT systems
Original title Liquid cooling for processors: How couplings from STAUFF’s QRC-FR series protect high-performance IT systems
STAUFF · Svenja Hausmann
A February 2026 STAUFF article giving the QRC-FR series DN 10 push-to-connect couplings for water-glycol circuits: 10 l/min nominal flow, 3.5 bar maximum pressure (also uncoupled) and -30 to +100 °C.
On this page
Overview
The article explains that GPUs and other processors gain power density with each hardware generation, that air cooling often can no longer remove the required heat reliably, and that liquid cooling avoids hotspots and keeps temperature stable. The reliability of the cooling circuit depends above all on connection technology working flawlessly.
It lists five requirements for connections in cooling circuits: leakage protection for the electronics, chemical resistance to water-glycol mixtures, temperature and pressure resistance under dynamic loads, compact design for limited space and low maintenance to reduce downtime.
The QRC-FR series push-to-connect couplings are designed for liquid cooling of high-performance electronic systems: stainless steel housing (1.4305, 1.4310), EPDM gaskets, nominal size DN 10 (3/8 inch), nominal flow of 10 l/min, maximum operating pressure of 3.5 bar also uncoupled, and a temperature range of -30 °C to +100 °C.
Applications named include high-performance broadcast transmission systems, CDUs for high-performance IT infrastructure and semiconductor or tube-based HF amplifiers. Adaptations are offered for special materials, alternative seals, different connection geometries and special media or temperature ranges. It is vendor content.
Key points
- The QRC-FR series is push-to-connect couplings designed for water-glycol mixtures.
- The housing is stainless steel (1.4305, 1.4310); gaskets are EPDM.
- Nominal size is DN 10 (3/8 inch) with a nominal flow of 10 l/min.
- Maximum operating pressure is 3.5 bar, also uncoupled.
- Temperature range is -30 °C to +100 °C.
- Connection requirements: leak protection, chemical resistance, temperature and pressure resistance, compact design, low maintenance.
- Applications include CDUs, HF amplifiers and broadcast transmitters.
- Other media need consultation; materials, seals and connection geometry can be customised.
Using it in design
- Compare the 10 l/min nominal flow with branch flow; a DN 10 line can be a bottleneck on branches above it.
- Verify that circuit operating pressure stays below the 3.5 bar limit, including the uncoupled state.
- Check EPDM seal and stainless housing compatibility with the glycol and inhibitor chemistry in use.
- Limit the number of connections and the frequency of disconnection during maintenance to reduce leak risk.
- Obtain manufacturer approval for any medium other than water-glycol.
Who should read it
Mechanical designers and equipment makers selecting couplings for CDU and in-rack liquid cooling circuits.
Document contents
- Increasing computing power, increasing temperatures
- Why liquid cooling is becoming a key technology for processors
- Requirements for secure connections in cooling circuits
- The STAUFF QRC-FR series at a glance
- Practical example: Liquid-cooled CDUs and high-performance electronics
- STAUFF advantages outside of classic hydraulics
- Customised solutions for specific cooling requirements
- The future of liquid cooling for processors
- FAQs
Publication details
- Authors
- Svenja Hausmann
- Publisher
- STAUFF
- Year
- 2026
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Svenja Hausmann (2026). Liquid cooling for processors: How couplings from STAUFF’s QRC-FR series protect high-performance IT systems. STAUFF. https://stauff.com/en/blog/applications/liquid-cooling-for-processors
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
