Technical guideFree to read2021

Veri Merkezlerinde Serbest Soğutma ve Trijenerasyon Uygulamaları Anlatıldı (Seminar report: free cooling and trigeneration in data centres)

Türk Tesisat Mühendisleri Derneği (TTMD) - TTMD Dergisi · C. Mutlu Tunç, M. Zeki Yılmazoğlu et al.

A report of TTMD's online seminar of 26 January 2021 on free cooling and trigeneration for data centres in Turkey.

On this page

Overview

This document is the report of an online seminar held by the Turkish Society of HVAC and Sanitary Engineers (TTMD) on 26 January 2021, published in TTMD Dergisi No. 129 (January-March 2021, p. 16). The seminar covers free cooling and trigeneration for data centres in Turkey. The speakers are C. Mutlu Tunç, M. Zeki Yılmazoğlu and Sinan Soğancı. The report is short, but it is one of the few Turkish sources on the effect of climate change on data-centre free cooling by city.

The first talk presents work done with Boğaziçi University's climate-change centre: the data-centre free-cooling potential of Istanbul, Ankara, İzmir, Konya and Erzurum was quantified and compared across 30-year climate periods. Inland cities away from the sea have relatively higher free-cooling potential; Konya has the highest and it is increasing. Istanbul has the lowest potential of the cities studied and it is decreasing. The stated goal is to extend the analysis to all 81 provinces so data centres can forecast future energy use and choose site and cooling system.

The second talk covers the benefits of cogeneration and trigeneration, part-load behaviour, heat-to-power ratios and ambient-temperature derating. The report stresses that CHP and trigeneration plants are usually sized for base load with fixed outputs, while data-centre and building loads vary daily and hourly, so matching electrical and thermal output is key. As a limit, this is a seminar report; it contains no detailed data, method or numerical result tables.

Key points

  1. Free-cooling potential was quantified for Istanbul, Ankara, İzmir, Konya and Erzurum and compared across 30-year climate periods.
  2. Inland cities away from the sea have relatively higher free-cooling potential; Konya has the highest and it is increasing.
  3. Istanbul has the lowest free-cooling potential of the cities studied and it is decreasing.
  4. Stated goal: extend the analysis to all 81 provinces so data centres can forecast future energy use and choose site and cooling system.
  5. CHP/trigeneration plants are usually sized for base load with fixed outputs, while data-centre and building loads vary, so matching electrical and thermal output is key.
  6. The seminar was held online on 26 January 2021; the report is in TTMD Dergisi No. 129.

Using it in design

  • In the site-selection tool, surface free-cooling hours by province for Turkish sites.
  • Flag coastal Istanbul sites as lower-potential.
  • Consider future-climate weather files rather than historical TMY only.
  • When evaluating trigeneration, account for part-load behaviour and ambient-temperature derating.

Monthly newsletter · free

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.

SoSo CAD

Check cooling capacity alongside your design

Review zone heat loads, available capacity and the capacity balance after the largest unit is lost in SoSo CAD.

Request a demo
Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Who should read it

Designers choosing data-centre sites and cooling systems in Turkey, HVAC engineers and energy planners.

Publication details

Authors
C. Mutlu Tunç; M. Zeki Yılmazoğlu; Sinan Soğancı
Publisher
Türk Tesisat Mühendisleri Derneği (TTMD) - TTMD Dergisi
Year
2021
Document number
TTMD Dergisi Sayı 129 (Ocak-Mart 2021), s. 16
Event
TTMD seminar (reported in TTMD Dergisi No. 129)
Document language
English
Source type
Industry body
Access
Free to read
Licence
Copyright retained; citation only — the publisher’s terms apply to the original document

Citation

C. Mutlu Tunç; M. Zeki Yılmazoğlu; Sinan Soğancı (2021). Veri Merkezlerinde Serbest Soğutma ve Trijenerasyon Uygulamaları Anlatıldı (Seminar report: free cooling and trigeneration in data centres). Türk Tesisat Mühendisleri Derneği (TTMD) - TTMD Dergisi. TTMD Dergisi Sayı 129 (Ocak-Mart 2021), s. 16. TTMD seminar (reported in TTMD Dergisi No. 129). https://www.ttmd.org.tr/upload/files/12020ttmd-dergisi-129.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.