U.S. Environmental Protection Agency, 2026, Guide or technical publication
EPA's WRAP 2.0 summer update lists the 27 new actions launched in April 2026, including data-centre cooling reuse actions 2.21, 3.10 and 8.12.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
U.S. Environmental Protection Agency, 2023, Guide or technical publication
An EPA and World Bank case study of the Quincy Water Reuse Utility, which treats a Microsoft data centre's cooling blowdown and returns it for cooling: operating since 2021, offsetting 138 million…
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
Türk Tesisat Mühendisleri Derneği (TTMD), 2022, Guide or technical publication
Report of the Turkish HVAC and Plumbing Engineers Association (TTMD) online seminar of 22 February 2022: pump room at most 49 C, 1 or 2 hour fire rated or 15.3 m from the building, drain pumps redund…
Guide or technical publication
2022
Read at publisher (opens in a new tab)↗
National Academy of Engineering, The Bridge vol. 56 no. 1, 2026, Guide or technical publication
An article arguing that rising AI chip power and liquid or two-phase cooling raise reject-heat temperatures enough to integrate data centres into heating and water-efficient energy systems.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2023, Guide or technical publication
The first white paper of the OCP Heat Reuse sub-project explains why data centre waste heat has so rarely been used, what has changed, and what makes a project viable. It is an introduction to projec…
Guide or technical publication
2023
PDF
Arup (Arup Foresight), 2025, Guide or technical publication
The first issue of Arup's foresight series, covering the energy-versus-water trade-off in heat rejection, how hyperscale growth concentrates water stress regionally, and balancing PUE and WUE by loca…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Jacobs, 2023, Guide or technical publication
This Jacobs white paper surveys measures to reduce data centre energy, water and embodied carbon. It offers a broad framework from cooling strategies and water reuse to low-carbon concrete and altern…
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
Data Center Frontier, 2026, Guide or technical publication
An article profiling Edged US's standardized AI campus model built around closed-loop waterless cooling from sister company ThermalWorks, with design targets for the Aurora and Irving projects.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Burns & McDonnell, 2024, Guide or technical publication
A five-page Burns & McDonnell white paper describing three liquid cooling approaches at the IT level (rear-door heat exchangers, direct-to-chip and immersion) and their effect on facility design.
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2025, Guide or technical publication
An OCP guideline for the hydrotest, cleaning, flushing and pre-commissioning of secondary TCS row-manifold pipework before CDUs and cold-plate racks are connected. Cold-plate channels are about 100…
Guide or technical publication
2025
PDF
National Laboratory of the Rockies (formerly NREL), 2026, Guide or technical publication
This page walks through the ESIF HPC data center cooling system in schematic steps: liquid cooling via CDUs for most heat, fan walls for residual air-cooled load, a closed energy-recovery water loop…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Consulting-Specifying Engineer, 2021, Guide or technical publication
A 2021 roundtable in which mission-critical engineers share data centre HVAC project results, with examples from PUE 1.15 down to 1.04 and leak protection.
Guide or technical publication
2021
Read at publisher (opens in a new tab)↗
Cundall (for Iceotope Technologies), 2021, Guide or technical publication
A desktop study by Cundall, commissioned by liquid-cooling vendor Iceotope, comparing chassis-level precision immersion cooling with best-practice air cooling. Vendor-sourced results should be read…
Guide or technical publication
2021
Read at publisher (opens in a new tab)↗
Cundall, 2024, Guide or technical publication
Cundall's Andrew Livesey compares direct and indirect evaporative air cooling, chiller-based liquid cooling and sea or river water cooling on the electricity-versus-water trade-off and argues that…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Lawrence Berkeley National Laboratory, Center of Expertise for Energy Efficiency in Data Centers, 2023, Guide or technical publication
The DOE's Excel-based tool, maintained by Lawrence Berkeley National Laboratory, that identifies savings from upgrades of server, storage and network equipment.
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
TMMOB Makina Mühendisleri Odası (MMO), 2009, Guide or technical publication
Hasan Acül's TESKON 2009 congress paper on water-side free cooling with dry coolers and chillers with integrated free-cooling coils, targeting 24/7 loads such as server rooms and data centres.
Guide or technical publication
2009
Read at publisher (opens in a new tab)↗
WSP, 2026, Guide or technical publication
WSP mechanical engineers' practical lessons from introducing liquid cooling in African data centres for GPU-based AI loads.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
The Green Grid, 2009, Guide or technical publication
A 2009 Green Grid map evaluating water-side economiser (free-cooling) potential across North America. Only the map is published; the underlying data are not available separately.
Guide or technical publication
2009
Read at publisher (opens in a new tab)↗
U.S. DOE Federal Energy Management Program / National Renewable Energy Laboratory, 2012, Guide or technical publication
This FEMP/NREL case study of the National Snow and Ice Data Center in Boulder describes a retrofit that replaced CRAC units with airside economization and multi-stage indirect evaporative coolers.…
Guide or technical publication
2012
Read at publisher (opens in a new tab)↗
Beca, 2026, Guide or technical publication
Beca's second article covering energy, cooling, water, resilience and decarbonisation, from raising cold-aisle temperatures to seismic restraint and AI loads.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Türk Tesisat Mühendisleri Derneği (TTMD) - TTMD Dergisi, 2021, Guide or technical publication
A TTMD-published Turkish translation of an ASHRAE Journal article summarising points from the ASHRAE TC 9.9 water-cooled servers paper, covering CDU versus direct connection, dew point, water quality…
Guide or technical publication
2021
Read at publisher (opens in a new tab)↗
Energy Efficient HPC Working Group / U.S. DOE FEMP, 2018, Guide or technical publication
Slides from an SC18 session with national-lab facility managers on warm-water liquid cooling, introducing a draft open specification for multi-vendor liquid-cooled racks.
Guide or technical publication
2018
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2022, Guide or technical publication
A Microsoft white paper submitted to OCP in 2022 that argues for warm-water liquid-cooled cloud facilities and examines how facility water temperature class trades device performance against chiller…
Guide or technical publication
2022
Read at publisher (opens in a new tab)↗
Uptime Institute Journal, 2025, Guide or technical publication
Uptime Institute Journal article explaining where water is actually consumed in a data center and how each site's water profile depends on climate, heat rejection technology and the local watershed.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗