T.C. Cumhurbaşkanlığı Siber Güvenlik Başkanlığı 2026

Bilgi ve İletişim Güvenliği Rehberi - 3.6.2 Sistem Odası/Veri Merkezine Yönelik Güvenlik Tedbirleri (Information and Communication Security Guide - measures for system rooms/data centres)

Provide a Turkey public-sector compliance checklist mapping the measures to design objects: dedicated IT UPS, N+1 air conditioning with auto changeover, redundant feeds, generator fuel redundancy, room adjacency checks against wet areas.

  • Water, power, humidity, temperature and smoke must be monitored with thresholds and alarms; monitoring must not be exposed externally (3.6.2.5).
RegulationFree to read

T.C. Enerji ve Tabii Kaynaklar Bakanlığı 2000

Elektrik Kuvvetli Akım Tesisleri Yönetmeliği (Turkish Regulation on Power Installations)

In the MV module (TR profile), select transformer primary protection automatically: fused load-break switch up to 400 kVA, fused load-break switch or relay-operated breaker up to 1,600 kVA, relay-operated breaker above.

  • Apparatus must be type-tested to applicable TS, otherwise EN, HD, IEC or VDE in that order (Article 10).
RegulationFree to read

Enerji Piyasası Düzenleme Kurumu (EPDK) 2021

Elektrik Piyasasında Depolama Faaliyetleri Yönetmeliği

Treat a grid-interactive data-centre battery as storage integrated with a consumption facility: same metering point and a distribution company connection opinion are required.

  • The regulation was published in Official Gazette No. 31479 on 9 May 2021.
RegulationFree to read

Kişisel Verileri Koruma Kurumu (KVKK) 2024

Regulation on the Procedures and Principles for the Transfer of Personal Data Abroad (Kişisel Verilerin Yurt Dışına Aktarılmasına İlişkin Usul ve Esaslar Hakkında Yönetmelik)

If SoSo CAD uses foreign sub-processors (cloud, email, monitoring), maintain an unmodified KVKK standard contract for each transfer path.

  • Standard contracts are published by the Board and must be used without modification (Article 14(2)-(3)).