ASHRAE 2010
Real-Time Energy Consumption Measurements in Data Centers (ASHRAE Datacom Series Book 9)
In a metering plan generator, define at design stage the meter points needed for PUE category reporting.
- Listed as a 2010 publication.
Collection
Citations and summaries of IEC, ISO, ASHRAE, NFPA, TIA and TSE standards.
73–96 / 114
ASHRAE 2010
In a metering plan generator, define at design stage the meter points needed for PUE category reporting.
BICSI ICT Today 2025
Catalogue liquid cooling systems with floor-load contribution, required sensors and cabling exit constraints (top-only for immersion).
ASHRAE 2008
Add floor-loading and seismic anchorage checks for racks to the design checklist, especially for AI racks of 1 t or more.
BICSI ICT Today 2026
Catalogue GPU cabinets with depth and 'rearAccess' flags and require front patching zones.
ASHRAE 2021
Primary reference for the thermal-class data used by the rule engine; record the edition (5th) per project.
IEEE 2025
Record the refrigerant (with pressure class and GWP) on two-phase CDU objects.
IEC 2022
In the UPS catalogue, record safety certification (IEC/EN 62040-1), installation location class (restricted access or ordinary-person area) and battery type.
IEC 2016
Store the EMC category (C1/C2/C3) in the UPS catalog.
IEC 2021
In the UPS catalogue, store the IEC 62040-3 classification (for example VFI-SS-111).
IEC 2013
In the sustainability catalogue, allow UPS environmental declaration fields (materials, end of life, use-phase losses).
IEC 2016
In the power topology, support DC-output UPS and rectifier plants as a source type for DC distribution designs.
ASHRAE 2023
The tool can compute 90.4 MLC and ELC directly from its mechanical and electrical one-lines: segment losses, UPS efficiency at 100/50/25% load and hourly weather by climate zone.
ASHRAE 2023
Evaluate all applicable inlet conditions (temperature, moisture, dew point, altitude) together.
BICSI 2024
Offer BICSI classes as an alternate standards profile alongside Uptime/TIA/EN, with an F1~Tier I/Rated-1/Class 1 ... F4~Tier IV/Rated-4/Class 4 table labelled 'conceptual equivalence only'
Telecommunications Industry Association 2024
In a 'TIA-942' standards profile, let users pick a rating per discipline (for example electrical Rated-3, mechanical Rated-3, telecom Rated-2)
ASHRAE TC 9.9 2016
Encode the A1-A4 table (dry bulb, dew point, altitude derate) as the canonical envelope lookup; site max inlet = classMax - (altitude-900)/derateStep.
ASHRAE TC 9.9 2021
Add class H1 and the W17/W27/W32/W40/W45/W+ facility-water classes to the thermal catalog as enumerations.
ASHRAE TC 9.9 2009
If an air-side economiser meets an urban or industrial site, prompt for corrosion coupon monitoring (G1 target) and MERV 11/13 makeup-air filtration.
NFPA 2024
Defaults for white space in NFPA jurisdictions: 1-hour rated walls, 3/4-hour doors and rated fire/smoke dampers at penetrations.
NFPA 2024
When the user selects VEWFD, auto-place aspirating sampling ports at no more than 200 ft2 (18.6 m2) each and check from pipe length that transport time is under 60 s.
ASHRAE TC 9.9 2015
In the zone model, define a thermal class per zone instead of one room setpoint (for example tape room A1/narrow, compute A2/A3).
Türk Standardları Enstitüsü (TSE) Year not stated
Express the reliability target as separate class selectors for power, cooling and cabling instead of one label.
Türk Standardları Enstitüsü (TSE) Year not stated
You may cite the designation 'TS EN 50600-3-1', but do not add an edition year until it is confirmed in the TSE catalogue.
Türk Standardları Enstitüsü (TSE) Year not stated
In new references, look to CLC/TS 50600-5-1:2023 rather than CLC/TR 50600-99-1.