Power and UPS

Collection: Power distribution, UPS, batteries, protection and redundant supply.

Sources
1317
Downloadable PDFs
105
Years
1984–2027

All sources

145–168 / 1317

Elektrik Tesislerinde Topraklamalar Yönetmeliği

T.C. Enerji ve Tabii Kaynaklar Bakanlığı, 2001, Regulation

Turkish earthing regulation for AC and DC installations below 100 Hz; it sets design conditions, minimum conductor sizes, the main earthing busbar and inspection/measurement periods.

Regulation

2001

PDF

¿Cómo instalar un Data Center en Chile?

Ministerio de Ciencia, Tecnología, Conocimiento e Innovación, Chile, 2025, Guide or technical publication

Chile's Ministry of Science guide (June 2025) lists energy feasibility, land use and permits for data-centre installation: environmental declaration (DIA) 12-18 months, building permit 6-8 months…

Guide or technical publication

2025

Read at publisher (opens in a new tab)

Selecting the Standard for Periodic Inspection of Building Electrical Installations: Comparative Application of TS HD 60364-6, TS EN 50678 and TS EN 50699

TMMOB Elektrik Mühendisleri Odası, 2026, Guide or technical publication

An article in EMO's Elektrik Muhendisligi issue 479 separates fixed-installation verification (TS HD 60364-6) from appliance testing (TS EN 50678, TS EN 50699), giving 1.0 MOhm (500 V DC) insulation…

Guide or technical publication

2026

Read at publisher (opens in a new tab)

Data Centres and Flexibility

IEA 4E EDNA, 2026, Guide or technical publication

IEA 4E EDNA platform report (June 2026): data-centre flexibility is assessed through three strategies (workload, supporting infrastructure, additional assets) across four data-centre types; workload…

Guide or technical publication

2026

Read at publisher (opens in a new tab)

Erkende maatregelenlijst (EML) 2023 v1.3 - Bijlage 10 Activiteitenregeling milieubeheer: categories Datacentrum (PH) and Serverruimte (FI)

Rijksdienst voor Ondernemend Nederland (RVO), 2023, Guide or technical publication

The Dutch list of recognised energy-saving measures that businesses under the energy-saving obligation must implement, with specific entries for data centres (processes) and server rooms of at least…

Guide or technical publication

2023

Read at publisher (opens in a new tab)