International Telecommunication Union (ITU-T), 2023, Guide or technical publication
ITU-T Recommendation L.1306, approved on 22 February 2023, specifies edge data centre infrastructure requirements for structure, power feeding, cooling, batteries and monitoring and control.
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2014, Guide or technical publication
ITU-T L.1320 (2014) defines efficiency formulas, test conditions and measurement setups for UPS, inverters, rectifiers, DC/DC converters, renewable sources and cooling equipment.
Guide or technical publication
2014
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2025, Guide or technical publication
ITU-T L.1322 (December 2025) defines a standard framework that evaluates data centre thermal performance at room, row, cabinet, device and chip level using indicators such as SHI; its appendix exampl…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2024, Guide or technical publication
ITU-T L.1327 (August 2024) defines a selection method that matches data centre cooling technology to climate, building storey count and business scenario (below 7 kW, 7 to 15 kW, 15 to 50 kW per rack…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Publications Office of the European Union, 2024, Guide or technical publication
Official publication metadata for the F-gas regulation. It provides a source reference for refrigerant and fluorinated-gas compliance research relevant to cooling and electrical equipment. This recor…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Netherlands Enterprise Agency (RVO), Year not stated, Guide or technical publication
The Netherlands Enterprise Agency RVO's data-centre heat-reuse page describes four arrangements with Dutch examples: a local heat-cold ring, direct supply nearby, direct internal use and indirect…
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Enterprise Singapore / Singapore Standards Council, 2023, Guide or technical publication
Singapore's 'Tropical DC' standard derives an energy-efficient environmental operating envelope for IT equipment in hot-humid climates from field data on production servers, and describes how to appl…
Guide or technical publication
2023
Paid, at publisher (opens in a new tab)↗
Enterprise Singapore / Singapore Standards Council, 2026, Guide or technical publication
A 70-page national standard, launched 27 August 2026, setting requirements and recommendations for direct liquid cooling in tropical data centres: planning and design, deployment and management, main…
Guide or technical publication
2026
Paid, at publisher (opens in a new tab)↗
Türk Tesisat Mühendisleri Derneği, 2011, Guide or technical publication
Sema Çelebi's article in TTMD Journal 75 (September-October 2011) on closed-loop and cooling tower water treatment; per Table 3, a 0.9 mm scale layer raises chiller energy consumption by about 30%.
Guide or technical publication
2011
Read at publisher (opens in a new tab)↗
PUB, Singapore’s National Water Agency, 2017, Guide or technical publication
PUB Singapore's November 2017 technical guide on cooling tower water balance, cycles of concentration (COC) optimisation, water quality and alternative sources; Green Mark rewards COC of 7 or more.
Guide or technical publication
2017
Read at publisher (opens in a new tab)↗
The Green Grid, 2024, Guide or technical publication
The Green Grid's spreadsheet tool, posted 24 January 2024, compares total cost of ownership of air and liquid cooling architectures; version 4.1 adds a workload-dependent liquid cooling efficiency…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Türk Tesisat Mühendisleri Derneği, 2026, Guide or technical publication
The 132-page 2026 TTMD proceedings include two data centre papers: PCNN reconstruction of temperature fields from sparse sensors (mean absolute error 0.75 degrees C, about 1 ms inference) and a guide…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
İSKİD, 2020, Guide or technical publication
ISKİD Alternative Refrigerants Seminar presentation (2020): hazards of R744, R717, R32, R1234ze, R290 and R1270, ISO 817 safety classes and EN 378 charge limits (R32 worked example: 8.84 kg).
Guide or technical publication
2020
Read at publisher (opens in a new tab)↗
Ahiler Kalkınma Ajansı, 2024, Guide or technical publication
Ahiler Development Agency's November 2024 study puts the initial cost of a Nevşehir underground (cave) data centre at an average of US$9.24 million, with Ankara 22% and Istanbul 45% higher and the…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Akademik Bilişim 2013 / Akdeniz Üniversitesi, 2013, Guide or technical publication
A five-page Turkish paper from the Akademik Bilişim 2013 conference (Akdeniz University, 23-25 January 2013) that introduces data centre design: energy, security, cooling, monitoring, raised floor…
Guide or technical publication
2013
Read at publisher (opens in a new tab)↗
U.S. Environmental Protection Agency, 2023, Guide or technical publication
An EPA and World Bank case study of the Quincy Water Reuse Utility, which treats a Microsoft data centre's cooling blowdown and returns it for cooling: operating since 2021, offsetting 138 million…
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2020, Guide or technical publication
A version 1.0 OCP white paper by JD.COM and Intel describing a redundant two-CDU direct-to-chip liquid cooling rack architecture, hose tests and node-level leak detection, with design figures.
Guide or technical publication
2020
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2025, Guide or technical publication
An OCP white paper that explains how pumped two-phase direct-to-chip cooling works, covering cold-plate physics, CDU types, manifolds, couplings and refrigerant choice. It is one of the few open refe…
Guide or technical publication
2025
PDF
Taiwan Ministry of Economic Affairs, 2025, Guide or technical publication
Official amendment adds a data-processing and hosting best-available-techniques annex covering IT choices, cooling, power and energy monitoring.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Energy Efficient HPC Working Group / Lawrence Berkeley National Laboratory, 2011, Guide or technical publication
A paper from the Energy Efficient HPC Working Group that derives, from climate data and step by step, the maximum building-supplied water temperatures for compressor-free cooling of supercomputers.
Guide or technical publication
2011
Read at publisher (opens in a new tab)↗
U.S. Environmental Protection Agency (ENERGY STAR), 2026, Guide or technical publication
ENERGY STAR's follow-on list of 16 energy-saving measures across IT, power infrastructure, airflow management and HVAC, with indicative savings ranges for each.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2024, Guide or technical publication
An OCP white paper arguing that silicon vendors and data centre operators should align on a "durable" 30 C technology cooling system (TCS) supply temperature for liquid-cooled AI hardware. It models…
Guide or technical publication
2024
PDF
U.S. Environmental Protection Agency (ENERGY STAR), 2026, Guide or technical publication
ENERGY STAR's entry-level list of five data centre energy measures, each backed by a headline savings figure or case example.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2021, Guide or technical publication
The OCP Advanced Cooling Solutions document defining mechanical, electrical, air-side and water-side requirements and test methods for active and passive rear-door heat exchangers on Open Rack.
Guide or technical publication
2021
Read at publisher (opens in a new tab)↗