İSKİD / Birol Kılkış, 2021, Guide or technical publication
A 2021 İSKİD seminar presentation by Prof. Birol Kılkış that compares cogeneration and trigeneration cases by first- and second-law efficiency and proposes RUE and RUEX instead of PUE for data centre…
Guide or technical publication
2021
Read at publisher (opens in a new tab)↗
Climate Neutral Data Centre Pact (CNDCP), 2024, Guide or technical publication
The CNDCP's 2021 workshop proposal sets a location-dependent maximum WUE with WUEmax = K0 x K1 x K2 x K3; the target is 0.4 L/kWh for potable water, cool climate and high water stress.
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Congressional Research Service, 2025, Guide or technical publication
US Congressional Research Service report R48646 (26 August 2025): US data centres used about 176 TWh in 2023, 4.4% of US electricity, and could double or triple by 2028 to reach up to 12%.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Netherlands Enterprise Agency (RVO), 2022, Guide or technical publication
RVO's October 2022 brochure describes Dutch practice in free cooling, chilled water, F-gas-free refrigerants and direct liquid cooling through case studies, with PUE of 1.1 and below in several cases.
Guide or technical publication
2022
Read at publisher (opens in a new tab)↗
Türk Tesisat Mühendisleri Derneği, 2020, Guide or technical publication
A TTMD Journal article (January-March 2020): in a metal processing plant, a free-cooling-assisted solution in place of a classical chiller cuts energy use 65.77 percent with a payback of about 3.22…
Guide or technical publication
2020
Read at publisher (opens in a new tab)↗
Bureau of Energy Efficiency (BEE), Ministry of Power, India, 2010, Guide or technical publication
A 2010 sourcebook from India's Bureau of Energy Efficiency (BEE, Ministry of Power), prepared with CII, to promote energy conservation in data centres and share practices across Indian facilities.
Guide or technical publication
2010
Read at publisher (opens in a new tab)↗
Rijksdienst voor Ondernemend Nederland (RVO), 2023, Guide or technical publication
The Dutch list of recognised energy-saving measures that businesses under the energy-saving obligation must implement, with specific entries for data centres (processes) and server rooms of at least…
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
Eurovent Certita Certification, Year not stated, Guide or technical publication
Eurovent Certita Certification's open directory lists certified dry cooler models with energy class, cooling capacity, 10 m sound pressure and fluid-side pressure drop at four fan speeds (very low…
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
BEAM Society Limited, 2020, Guide or technical publication
The March 2020 BEAM Society guide from Hong Kong lists best practices across 11 sections covering the whole data-centre life cycle, each with qualitative effort and effectiveness ratings on a 1 to 5…
Guide or technical publication
2020
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2024, Guide or technical publication
An OCP guideline describing pumpless two-phase cooling loops, loop heat pipe (LHP) systems that move fluid from chip evaporators to a rack condenser by capillary action and gravity. It was written…
Guide or technical publication
2024
PDF
TMMOB Makina Mühendisleri Odası, 2007, Guide or technical publication
A 2007 congress paper by Ali and Senem Güngör on energy audit types, chiller replacement and control, and economiser cycles; scroll chillers exceed COP 3.2 and a 20% fan speed cut saves about 50%…
Guide or technical publication
2007
Read at publisher (opens in a new tab)↗
İSKİD, 2021, Guide or technical publication
An April 2021 presentation prepared for ISKİD: the EU Ecodesign (ErP) framework, LOT 10, LOT 1/2 and EU 2016/2281 (LOT 21) rules for air conditioners, rooftops and chillers above 12 kW, with Turkish…
Guide or technical publication
2021
Read at publisher (opens in a new tab)↗
İSKİD, 2021, Guide or technical publication
A 2021 ISKİD presentation by Toros Arslanyan: absorption chiller types (LiBr-water, ammonia-water) from cogeneration to trigeneration, with working principles and comparison of open and closed coolin…
Guide or technical publication
2021
Read at publisher (opens in a new tab)↗
Eurovent Certita Certification, Year not stated, Guide or technical publication
Eurovent Certita's LCP-HP programme covers electric liquid chilling packages and hydronic heat pumps, with a certify-all rule and condition codes such as A35/W12-7, and publishes certified values in…
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
İSKİD / Sönmez Global, 2021, Guide or technical publication
A 2021 presentation by Nejat Babür of Sönmez Global for İSKİD: keep generator room summer temperature below 40 C, expect 15-18% capacity loss at 49 C, size the radiator fan for 125-175 Pa external…
Guide or technical publication
2021
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2026, Guide or technical publication
A completed OCP Ready v1 self-assessment for QScale Q01 (Lévis, Canada): 28 MW IT, 2N feeds, design PUE below 1.2 and support for 400 kW+ liquid-cooled racks meet the OCP requirements.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2026, Guide or technical publication
A completed OCP Ready v2 hyperscale self-assessment for Aligned PHX04 (Chandler, USA): 50.7 MW critical IT, Tier 3-class power and cooling, and design PUE below 1.3 at 80% utilisation.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Open Compute Project (GitHub: opencomputeproject), Year not stated, Guide or technical publication
An open-source Python/Jupyter tool from the Open Compute Project that gives order-of-magnitude capital and operating cost estimates for the data-centre heat exchanger interface to a heat network.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Danish Energy Agency, Year not stated, Guide or technical publication
Per the Danish Energy Agency, from 11 October 2025 data centres above 1 MW must prepare and submit for approval a surplus-heat cost-benefit analysis when built or substantially renovated.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation (Meta contribution), 2023, Guide or technical publication
Case studies from Meta's Zion and Grand Teton AI training platforms comparing the cooling limits of air, air-assisted liquid cooling and facility water cooling, with lessons from three generations…
Guide or technical publication
2023
PDF
Eurovent Certita Certification, Year not stated, Guide or technical publication
Eurovent Certita's ITCU programme covers IT cooling units (CRAC and CRAH) and hybrids, and defines certified criteria such as Pc, net sensible Ps, EER, net SHR, airflow and EN ISO 16890 filter grade.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2026, Guide or technical publication
Google's OCP Project Brazos v0.75.4 (11 September 2026) specification defines a three-module, closed-loop liquid-to-air (aCDU) rack-side cooling system rejecting 60 kW beside an ORV3 rack.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2014, Guide or technical publication
ITU-T Recommendation L.1300 (2014) replaces the 2011 edition and is a 68-page reference of numbered best practices covering planning, ICT equipment, cooling, power, building, monitoring, network and…
Guide or technical publication
2014
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2019, Guide or technical publication
ITU-T L.1305 (11/2019) is an in-force recommendation specifying a DCIM system: principles, managed objects, data collection, energy-saving and capacity management, and AI control of cooling.
Guide or technical publication
2019
Read at publisher (opens in a new tab)↗