Uptime Institute, 2026, Guide or technical publication
A 2026 Uptime Institute report on how weaknesses in facility operational technology (OT) protocols and web consoles can open paths into data centre facility networks.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Danish Energy Agency, Year not stated, Guide or technical publication
Per the Danish Energy Agency, from 11 October 2025 data centres above 1 MW must prepare and submit for approval a surplus-heat cost-benefit analysis when built or substantially renovated.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Ministerio de Ciencia, Tecnología, Conocimiento e Innovación, Chile, 2024, Guide or technical publication
Chile's National Data Centre Plan (PDATA) 2024-2030, from the Ministry of Science, sets eight measures for an industry at 198 MW installed: a permit guide, SEIA environmental criteria, clean producti…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Planning Institute of Australia, 2026, Guide or technical publication
The Planning Institute of Australia's 2026 guidance note ties data-centre scale to site suitability and assessment evidence, and suggests operating conditions for noise, generator tests, water use…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
PLANMalaysia, Ministry of Housing and Local Government, 2024, Guide or technical publication
PLANMalaysia's 2024 guideline links site hazards, utility consultation and planning submission routes for new sites and building conversions, calling for consultation with TNB and water authorities…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Building Commissioning Association, 2019, Guide or technical publication
Covers responsibilities, communications, risk assessment and procedures for power loss and recovery tests.
Guide or technical publication
2019
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation (Meta contribution), 2023, Guide or technical publication
Case studies from Meta's Zion and Grand Teton AI training platforms comparing the cooling limits of air, air-assisted liquid cooling and facility water cooling, with lessons from three generations…
Guide or technical publication
2023
PDF
Eurovent Certita Certification, Year not stated, Guide or technical publication
Eurovent Certita's ITCU programme covers IT cooling units (CRAC and CRAH) and hybrids, and defines certified criteria such as Pc, net sensible Ps, EER, net SHR, airflow and EN ISO 16890 filter grade.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Cybersecurity and Infrastructure Security Agency (CISA), 2025, Guide or technical publication
A joint US agency fact sheet of 6 May 2025 lists five primary OT mitigations: remove internet exposure, change default passwords, secure remote access, segment IT and OT, and keep the ability to oper…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2026, Guide or technical publication
Google's OCP Project Brazos v0.75.4 (11 September 2026) specification defines a three-module, closed-loop liquid-to-air (aCDU) rack-side cooling system rejecting 60 kW beside an ORV3 rack.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Netherlands Enterprise Agency (RVO), Year not stated, Guide or technical publication
Dutch RVO guidance: data centres with at least 500 kW installed IT power report their energy efficiency every year (16 March to 15 May in 2026); 36% of EU data centres, or 770 sites, took part.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2014, Guide or technical publication
ITU-T Recommendation L.1300 (2014) replaces the 2011 edition and is a 68-page reference of numbered best practices covering planning, ICT equipment, cooling, power, building, monitoring, network and…
Guide or technical publication
2014
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2015, Guide or technical publication
ITU-T L.1301 (2015) defines the minimum static and dynamic data set to collect from ICT and facility equipment for data-centre energy management; suggested power measurement accuracy is ±2%.
Guide or technical publication
2015
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2015, Guide or technical publication
ITU-T L.1302 (2015) gives the method for calculating an operating data centre's PUE, pPUE, power-feeding efficiency and cooling CLF, using a 12-month assessment, measurement at least every 30 minutes…
Guide or technical publication
2015
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2019, Guide or technical publication
ITU-T L.1305 (11/2019) is an in-force recommendation specifying a DCIM system: principles, managed objects, data collection, energy-saving and capacity management, and AI control of cooling.
Guide or technical publication
2019
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2023, Guide or technical publication
ITU-T Recommendation L.1306, approved on 22 February 2023, specifies edge data centre infrastructure requirements for structure, power feeding, cooling, batteries and monitoring and control.
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2024, Guide or technical publication
ITU-T L.1307 (March 2024) defines design requirements for micro data centres and an indicator, EEI(MDC) = ITEUsv / PUE, that relates server CPU utilisation to PUE; it recommends 5-10 minutes of UPS…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2025, Guide or technical publication
ITU-T Recommendation L.1308 (December 2025) advises new low-carbon data centres to target an annual PUE of 1.3 in cool and 1.4 in warm climates, with a 75% renewable energy factor.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2014, Guide or technical publication
ITU-T L.1320 (2014) defines efficiency formulas, test conditions and measurement setups for UPS, inverters, rectifiers, DC/DC converters, renewable sources and cooling equipment.
Guide or technical publication
2014
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2025, Guide or technical publication
ITU-T L.1322 (December 2025) defines a standard framework that evaluates data centre thermal performance at room, row, cabinet, device and chip level using indicators such as SHI; its appendix exampl…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2024, Guide or technical publication
ITU-T L.1327 (August 2024) defines a selection method that matches data centre cooling technology to climate, building storey count and business scenario (below 7 kW, 7 to 15 kW, 15 to 50 kW per rack…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Publications Office of the European Union, 2023, Guide or technical publication
Original-act metadata for the EU batteries and waste-batteries regulation, relevant to researching the lifecycle obligations associated with battery-backed power systems. The publisher warns that a…
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
Publications Office of the European Union, 2024, Guide or technical publication
Official publication metadata for the F-gas regulation. It provides a source reference for refrigerant and fluorinated-gas compliance research relevant to cooling and electrical equipment. This recor…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
International Renewable Energy Agency, 2026, Guide or technical publication
IRENA summary (July 2026): in 2025 solar PV LCOE was USD 44, onshore wind USD 33 and offshore wind USD 78/MWh, and over 90% of new utility-scale renewable capacity was cheaper than the cheapest new…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗