Infocomm Media Development Authority (IMDA), 2026, Guide or technical publication
Singapore IMDA request for information (20 March 2026): servers and storage that are ENERGY STAR certified and meet at least ASHRAE Class A2 can be pre-approved for the Energy Efficiency Grant; submi…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Netherlands Enterprise Agency (RVO), Year not stated, Guide or technical publication
The Netherlands Enterprise Agency RVO's data-centre heat-reuse page describes four arrangements with Dutch examples: a local heat-cold ring, direct supply nearby, direct internal use and indirect…
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
EPRI (Electric Power Research Institute), 2026, Guide or technical publication
An EPRI white paper of October 2026 (3002034920): drawing on a global failure database, it finds lithium-ion BESS failures per deployed GWh fell 98% from 2018 to 2025 and are on the same order as…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2026, Guide or technical publication
OCP Rope Leak Sensor Rev 1.0.0 (Feb 2026) defines a 4-pin, 3.3-12 Vdc, tach-output leak sensor interface and alarm signal logic for direct-to-chip servers using water-based coolant.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
PUB, Singapore’s National Water Agency, 2025, Guide or technical publication
A December 2025 page from Singapore's national water agency PUB publishing a data-centre median water efficiency index of 2.1 m³/MWh, derived from mandatory large-user submissions.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Open Compute Project, 2025, Guide or technical publication
An OCP specification defining a protocol for recovering corrupted device firmware over SMBus, I3C and USB. Its revision history separates the 2025 additions (USB, I3C, flashless boot, multi-stage…
Guide or technical publication
2025
PDF
NIST, 2026, Guide or technical publication
NIST's July 2026 draft SP 800-209r1 offers threat-mapped storage security controls covering block, file and object storage plus software-defined and cloud storage, and applies to AI/ML storage as…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2024, Guide or technical publication
A short two-page OCP guide written for municipal planners on enabling data-centre heat reuse. It summarises offtake uses, barriers and the steps local authorities can take, and is useful for planning…
Guide or technical publication
2024
PDF
Ulaştırma, Denizcilik ve Haberleşme Bakanlığı / Haberleşme Genel Müdürlüğü, 2014, Guide or technical publication
A November 2014 Turkish guide defining how sectoral cyber incident response teams are set up in the energy, communications, finance, water, transport and critical public service sectors, and how they…
Guide or technical publication
2014
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2026, Guide or technical publication
An OCP guideline defining the test flow that checks whether server components such as cables, connectors, optics, plastics, elastomers and adhesives and dielectric immersion fluids degrade each other…
Guide or technical publication
2026
PDF
Swiss Re Institute, 2026, Guide or technical publication
Swiss Re Institute's Sigma Insights 07/2026 looks at concentrated asset value in large AI data centres and the physical risks from natural hazards, cooling-water damage, power continuity and on-site…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2026, Guide or technical publication
An early-draft black-box interface specification from Google, Microsoft and NVIDIA for megawatt-scale medium-voltage solid-state transformers that replace the line-frequency MV transformer and rectif…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Enterprise Singapore / Singapore Standards Council, 2023, Guide or technical publication
Singapore's 'Tropical DC' standard derives an energy-efficient environmental operating envelope for IT equipment in hot-humid climates from field data on production servers, and describes how to appl…
Guide or technical publication
2023
Paid, at publisher (opens in a new tab)↗
Enterprise Singapore / Singapore Standards Council, 2025, Guide or technical publication
National standard setting energy-efficiency requirements and guidance for selecting, deploying and operating servers, storage and network equipment in data centres, for new installs, replacements…
Guide or technical publication
2025
Paid, at publisher (opens in a new tab)↗
Enterprise Singapore / Singapore Standards Council, 2026, Guide or technical publication
A 70-page national standard, launched 27 August 2026, setting requirements and recommendations for direct liquid cooling in tropical data centres: planning and design, deployment and management, main…
Guide or technical publication
2026
Paid, at publisher (opens in a new tab)↗
Bureau of Energy Efficiency / Confederation of Indian Industry, Year not stated, Guide or technical publication
The Karnataka plan, prepared by CII for BEE, sets sector strategies to 2031; its data-centre strategy takes PUE from 2.0 to 1.5 (moderate) or 1.2 (ambitious) for savings of 0.08 to 0.12 MTOE.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
CPSE Center for Innovation, 2026, Guide or technical publication
A CPSE survey of November 2026: of 122 US fire chiefs, 68% say data-centre growth will require significant changes to fire department planning, and 90.5% are concerned about lithium-ion fires and…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Türk Tesisat Mühendisleri Derneği, 2011, Guide or technical publication
Sema Çelebi's article in TTMD Journal 75 (September-October 2011) on closed-loop and cooling tower water treatment; per Table 3, a 0.9 mm scale layer raises chiller energy consumption by about 30%.
Guide or technical publication
2011
Read at publisher (opens in a new tab)↗
Uptime Institute, 2026, Guide or technical publication
A 2026 Uptime Institute report on data centre IT and OT supply chain cyber risk, changes in connected vendors, systems and personnel, and third parties with permanent or intermittent access.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Electrical and Mechanical Services Department, Hong Kong, 2026, Guide or technical publication
Hong Kong EMSD guideline of about 75 pages: scope of the energy audit, central services boundary for data-centre portions of industrial buildings, a 5-year audit interval and EAC 2024 requirements…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
PUB, Singapore’s National Water Agency, 2017, Guide or technical publication
PUB Singapore's November 2017 technical guide on cooling tower water balance, cycles of concentration (COC) optimisation, water quality and alternative sources; Green Mark rewards COC of 7 or more.
Guide or technical publication
2017
Read at publisher (opens in a new tab)↗
Texas Legislature, 2025, Guide or technical publication
Texas law signed on 20 June 2025 setting rules for large loads (75 MW and above by default) connecting to the ERCOT grid.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
The Green Grid, 2024, Guide or technical publication
The Green Grid's spreadsheet tool, posted 24 January 2024, compares total cost of ownership of air and liquid cooling architectures; version 4.1 adds a workload-dependent liquid cooling efficiency…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
The Green Grid, 2024, Guide or technical publication
The Green Grid's SEED v2.0 spreadsheet, dated 28 June 2024, holds anonymised server energy-efficiency data collected from multiple equipment manufacturers and is updated as new data arrive.
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗