Agencia de Gobierno Electrónico y Sociedad de la Información y del Conocimiento (Agesic), Year not stated, Guide or technical publication
Agesic's MCU 5.0 guidance for Uruguay sets four maturity levels (13 controls) of physical access control for data centres, including no windows on outer walls, visitor logging with purpose, and an…
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
U.S. Environmental Protection Agency, 2026, Guide or technical publication
US EPA's January 2026 guidance EPA-540-S-26-001: criteria for evaluating Superfund and Brownfield sites for data centres, including at least 100 acres for a 100 MW campus, 2-5% slope, flood zone and…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Direction générale des Entreprises, 2025, Guide or technical publication
France's DGE guide (November 2025) helps local authorities and project owners site data centres: grid connection takes 2-3 to 6-9 years, large projects average 50-250 MW, and operations create about…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
ETMD, Elektrik Tesisat Mühendisleri Derneği, 2024, Guide or technical publication
A Teksan technical article in issue 114 of the ETMD magazine setting out layout rules for the generator room floor, arrangement, ventilation, fuel and exhaust, and listing common mistakes such as…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
PLANMalaysia Johor, 2024, Guide or technical publication
PLANMalaysia Johor's April 2024 guidelines split data centres into 1-5, 5-20 and 21-100 MW scales and set commercial-zone rules of at least 2 acres, 6 floors or 27 m height, 12 m setbacks and a 50 m…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
South Africa Department of Communications and Digital Technologies, 2024, Guide or technical publication
South African policy for data and cloud infrastructure, covering resource constraints, government hosting and continuity. The infrastructure section calls for backup water and electricity because of…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
EnergieSchweiz, Bundesamt für Energie, Year not stated, Guide or technical publication
EnergieSchweiz planning guide for cantons and municipalities: Schaffhausen requires PUE+ of at most 1.20 within three years of commissioning, and up to 80% of a data centre's electricity could be…
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Iowa Department of Natural Resources, Year not stated, Guide or technical publication
Iowa Department of Natural Resources web guide: there is no single data-centre permit; withdrawals of 25,000 gallons or more per 24 hours, air, stormwater, wastewater and floodplain each need their…
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
National Information Technology Agency / Ghana Business Regulatory Reforms Portal, 2024, Guide or technical publication
Data-centre-specific consultation framework that combines registration evidence with technical design guidance. For two main distribution areas it calls for diverse cable routes, separate fire zones…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Central Bank of Nigeria, Year not stated, Guide or technical publication
The Central Bank of Nigeria's IT standards page sets a minimum Level 3 maturity for financial services and a Tier 3 data centre target (99.982% availability) based on TIA-942 and Uptime.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
UK Government, 2026, Guide or technical publication
The UK government's Data Centre Covenant: a target of 6 GW of AI data centre capacity by 2030, PUE of 1.3 or better for new facilities, and priority grid connection for strategic data centres.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Ministerio de Ciencia, Tecnología, Conocimiento e Innovación, Chile, 2025, Guide or technical publication
Chile's Ministry of Science guide (June 2025) lists energy feasibility, land use and permits for data-centre installation: environmental declaration (DIA) 12-18 months, building permit 6-8 months…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
TMMOB Makina Mühendisleri Odası, 2023, Guide or technical publication
Two papers from the TESKON 2023 proceedings: seismic restraint of mechanical services costs no more than 1% of mechanical cost and 0.3% of building cost; fire dampers must be tested to EN 1366-2 or…
Guide or technical publication
2023
Read at publisher (opens in a new tab)↗
North American Electric Reliability Corporation (NERC), 2026, Guide or technical publication
NERC's 2025 LTRA: 13 of 23 assessment areas face resource adequacy challenges over 10 years, summer peak demand is forecast to rise 224 GW, and data centres account for most of the growth.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
British Geological Survey, 2026, Guide or technical publication
British Geological Survey 2026 seismic hazard maps give PGA and spectral acceleration for five return periods from 95 to 5000 years; at 475 years PGA is about 0.04 g across much of the offshore EEZ.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
RAND, 2026, Guide or technical publication
RAND report RR-A5050-1 presents a quantitative model that ranks 31 candidate federal locations for a 1 GW data centre under four generation scenarios by energy infrastructure cost and readiness.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
UK Government (GOV.UK), 2025, Guide or technical publication
UK government plan (13 January 2025) for AI adoption and infrastructure.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
EirGrid and SONI, 2026, Guide or technical publication
EirGrid and SONI 10-year report: Ireland is outside its 3-hour LOLE reliability standard in 2026-2028, and data centre and new technology load rises from 959 MVA in 2024 to 1,870 MVA by 2035 in the…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Danish Energy Agency (Energistyrelsen), 2026, Guide or technical publication
Danish Energy Agency note (October 2026): data-centre electricity demand is projected from a maturity-weighted Energinet grid-connection pipeline and a European market-share model, cutting the long-t…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
BEAM Society Limited, 2021, Guide or technical publication
BEAM Society Limited's September 2021 green-building assessment manual for new Hong Kong data centres: energy carries 40% of the weighting, design PUE is scored from 1.77 to 1.52, and the prerequisit…
Guide or technical publication
2021
Read at publisher (opens in a new tab)↗
American Water Works Association / Carollo Engineers, 2026, Guide or technical publication
A 2026 AWWA report with Carollo Engineers that gives water utilities criteria for judging each data-centre project on demand, supply reliability, financial exposure and public communication.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
American Water Works Association, 2025, Guide or technical publication
AWWA's October 2025 report on data-centre impacts on water utilities (demand, infrastructure, cost, energy, regulation) with an eight-point planning framework; direct consumption is projected from…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Servicio de Evaluación Ambiental, Chile, 2026, Guide or technical publication
Chile's Environmental Assessment Service (SEA) first-edition criterion of January 2026: SEIA entry for data centres is case by case, mainly through hazardous substances (80,000 kg) and secondarily…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Monroe County Planning Commission, 2026, Guide or technical publication
The Monroe County Planning Commission guide in Pennsylvania recommends assessing utility plans, emergency service capability and environmental review processes before a proposal arrives.
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗