Shaking-table tests of server cabinets
Engineering Structures (Elsevier), 2024, Research paper
Experimental investigation of server-cabinet response and fragility.
Research paper
2024
Type a quantity or a design decision. Each answer comes with the document and page it was taken from.
1153–1176 / 2,875 documents
Engineering Structures (Elsevier), 2024, Research paper
Experimental investigation of server-cabinet response and fragility.
Research paper
2024
Energies / MDPI, 2025, Research paper
An Energies (2025) paper reports that a microchannel heat-pipe evaporative condensation unit reaches 112.1, 105.8 and 115.4 kW in dry, wet and mixed modes, with an optimal refrigerant charge of 32 kg.
Research paper
2025
Thermal Science and Engineering Progress (Elsevier BV), 2026, Research paper
A Thermal Science and Engineering Progress paper reporting that a micro-heat-pipe array raises critical heat flux from 27.76 to 106 W/cm², with annual average PUE of 1.046-1.064 in six Chinese cities.
Research paper
2026
Case Studies in Thermal Engineering (Elsevier BV), 2024, Research paper
A 2024 Case Studies in Thermal Engineering study of a GPU-server single-phase immersion tank: inlet coolant from 20 to 50 °C raises outlet by 30 °C but mean GPU temperature by only 21 °C.
Research paper
2024
Energy Efficiency (Springer Science and Business Media LLC), 2024, Research paper
An open-access Energy Efficiency paper interviews 16 experts and operators on non-technical barriers to efficiency; vendor relationships, fragmented non-PUE metrics and IT-facilities silos stand out.
Research paper
2024
Bozok Journal of Engineering and Architecture, 2024, Research paper
A Bozok Journal of Engineering and Architecture paper (2024): modelling a 10 kVA UPS battery string (8 x 12 V in series) as one three-parameter Thevenin circuit gives 99.85% average accuracy in SoC…
Research paper
2024
University of Pretoria, 2008, Research paper
A 2008 MBA dissertation at the University of Pretoria uses 19 interviews to gauge South African organisations' data-centre energy awareness; consolidation emerges as the main factor and cost as the…
Research paper
2008
Engineering Failure Analysis (Elsevier), 2026, Research paper
Case investigation of cracked condenser tubes in a data-centre cooling system.
Research paper
2026
Trinity College Dublin / author conference manuscript, Year not stated, Research paper
A two-page Trinity College Dublin manuscript showing that stackable metamaterial rings added to an 80 mm fan cut a targeted 4150 Hz tone by about 10.8 dB with six rings in this setup.
Research paper
-
Fire (MDPI AG), 2026, Research paper
A 2026 Fire (MDPI) study combining grey relational analysis, system dynamics and FDS for a 30 ft containerised lithium-ion BESS: without suppression, high temperature spreads along the module layer…
Research paper
2026
European Journal of Science and Technology, 2018, Research paper
Güğül's 2018 EJOSAT paper: using Ankara measurements, free cooling share and PUE are calculated for six Turkish cities; PUE is 1.23, 1.37 and 1.37 in Erzurum, Ankara and Konya, and Antalya saves 46…
Research paper
2018
Sustainability (MDPI AG), 2023, Research paper
The 2023 Sustainability article (DOI 10.3390/su152115249) proposes the GEECO model, which adjusts workload distribution and task assignment dynamically to cut energy use and carbon emissions in cloud…
Research paper
2023
IEEE Access (Institute of Electrical and Electronics Engineers (IEEE)), 2025, Research paper
An IEEE Access (2025) paper by Frederick and Manohara Pai: a GenAI pipeline that processes CRM records and field service reports to predict UPS failures reaches weighted accuracy and precision above…
Research paper
2025
Applied Energy (Elsevier BV), 2026, Research paper
A 2026 Applied Energy paper compares the training and inference footprint of generative AI across data-centre architectures from edge to AI-dedicated facilities in a 20-year life cycle simulation.
Research paper
2026
İstanbul Aydın Üniversitesi Anadolu Bil Meslek Yüksekokulu Dergisi, 2025, Research paper
Jobani and Kaya (Istanbul Aydin University, 2025) manage solar, wind, diesel and UPS sources with machine learning and report, in simulation, a 50.1% renewable share and up to 20% lower energy use.
Research paper
2025
Science and Technology for Energy Transition (EDP Sciences), 2024, Research paper
A 2024 review in Science and Technology for Energy Transition comparing single-phase and two-phase immersion cooling; in China data centres use about 4% of electricity and cooling 30-50% of site ener…
Research paper
2024
Journal of Physics: Conference Series (IOP Publishing), 2026, Research paper
An IOP conference paper using a validated CFD model to compare two-phase immersion coolants: SF-33 and Novec 7000 cool best, and SF-33 needs 0.387 m³/h less flow than Novec 649.
Research paper
2026
Applied Energy (Elsevier), 2024, Research paper
The Applied Energy article (cover date March 2024, DOI 10.1016/j.apenergy.2023.122473) models and compares waste-heat recovery systems for liquid-cooled data centres and building space heating networ…
Research paper
2024
Future Internet (MDPI), 2025, Research paper
A 2025 review in Future Internet on extending RDMA across data centres, covering congestion control and load balancing; the authors present it as the first review article focused on inter-DC RDMA.
Research paper
2025
IEEE / Energy Efficient High Performance Computing Working Group, 2020, Research paper
The EE HPC Working Group's IEEE CLUSTER 2020 report concludes that HPC data centres need their own electrical commissioning guidelines because of dense, fluctuating compute loads.
Research paper
2020
Avrupa Bilim ve Teknoloji Dergisi, 2021, Research paper
A 2021 paper by authors from Tescom and Izmir Katip Celebi University: on a 5 kW UPS inverter the gain scheduling adaptive PI controller cuts output voltage THD from 1.7% for conventional PI to 0.9%…
Research paper
2021
Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, 2022, Research paper
Erden and Türkmen (Gazi University Faculty of Engineering and Architecture Journal, 2022) calculate a 1.6-year payback for CRAH bypass in a 180 m² small data centre, with 8 induced (iBP) or 7 forced…
Research paper
2022
Energies (MDPI AG), 2026, Research paper
A 2026 open-access review that gives a structured account of how data-centre workload, cooling, UPS, battery and backup resources can become flexible, grid-supporting resources in renewable-rich grid…
Research paper
2026
Energy and Buildings (Elsevier BV), 2026, Research paper
A 2026 Energy and Buildings paper gives the first full-year field data on dew point evaporative cooling in a live UK edge data centre: annual mean COP about 30, falling to about 18 in a hot July peri…
Research paper
2026