International Telecommunication Union (ITU-T), 2014, Guide or technical publication
ITU-T Recommendation L.1300 (2014) replaces the 2011 edition and is a 68-page reference of numbered best practices covering planning, ICT equipment, cooling, power, building, monitoring, network and…
Guide or technical publication
2014
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2015, Guide or technical publication
ITU-T L.1301 (2015) defines the minimum static and dynamic data set to collect from ICT and facility equipment for data-centre energy management; suggested power measurement accuracy is ±2%.
Guide or technical publication
2015
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2015, Guide or technical publication
ITU-T L.1302 (2015) gives the method for calculating an operating data centre's PUE, pPUE, power-feeding efficiency and cooling CLF, using a 12-month assessment, measurement at least every 30 minutes…
Guide or technical publication
2015
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2019, Guide or technical publication
ITU-T L.1305 (11/2019) is an in-force recommendation specifying a DCIM system: principles, managed objects, data collection, energy-saving and capacity management, and AI control of cooling.
Guide or technical publication
2019
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2024, Guide or technical publication
ITU-T L.1307 (March 2024) defines design requirements for micro data centres and an indicator, EEI(MDC) = ITEUsv / PUE, that relates server CPU utilisation to PUE; it recommends 5-10 minutes of UPS…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2024, Guide or technical publication
ITU-T L.1327 (August 2024) defines a selection method that matches data centre cooling technology to climate, building storey count and business scenario (below 7 kW, 7 to 15 kW, 15 to 50 kW per rack…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
International Renewable Energy Agency, 2026, Guide or technical publication
IRENA summary (July 2026): in 2025 solar PV LCOE was USD 44, onshore wind USD 33 and offshore wind USD 78/MWh, and over 90% of new utility-scale renewable capacity was cheaper than the cheapest new…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Infocomm Media Development Authority (IMDA), 2026, Guide or technical publication
Singapore IMDA request for information (20 March 2026): servers and storage that are ENERGY STAR certified and meet at least ASHRAE Class A2 can be pre-approved for the Energy Efficiency Grant; submi…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Netherlands Enterprise Agency (RVO), Year not stated, Guide or technical publication
The Netherlands Enterprise Agency RVO's data-centre heat-reuse page describes four arrangements with Dutch examples: a local heat-cold ring, direct supply nearby, direct internal use and indirect…
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, 2024, Guide or technical publication
A short two-page OCP guide written for municipal planners on enabling data-centre heat reuse. It summarises offtake uses, barriers and the steps local authorities can take, and is useful for planning…
Guide or technical publication
2024
PDF
Enterprise Singapore / Singapore Standards Council, 2023, Guide or technical publication
Singapore's 'Tropical DC' standard derives an energy-efficient environmental operating envelope for IT equipment in hot-humid climates from field data on production servers, and describes how to appl…
Guide or technical publication
2023
Paid, at publisher (opens in a new tab)↗
Enterprise Singapore / Singapore Standards Council, 2025, Guide or technical publication
National standard setting energy-efficiency requirements and guidance for selecting, deploying and operating servers, storage and network equipment in data centres, for new installs, replacements…
Guide or technical publication
2025
Paid, at publisher (opens in a new tab)↗
Bureau of Energy Efficiency / Confederation of Indian Industry, Year not stated, Guide or technical publication
The Karnataka plan, prepared by CII for BEE, sets sector strategies to 2031; its data-centre strategy takes PUE from 2.0 to 1.5 (moderate) or 1.2 (ambitious) for savings of 0.08 to 0.12 MTOE.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Türk Tesisat Mühendisleri Derneği, 2011, Guide or technical publication
Sema Çelebi's article in TTMD Journal 75 (September-October 2011) on closed-loop and cooling tower water treatment; per Table 3, a 0.9 mm scale layer raises chiller energy consumption by about 30%.
Guide or technical publication
2011
Read at publisher (opens in a new tab)↗
Electrical and Mechanical Services Department, Hong Kong, 2026, Guide or technical publication
Hong Kong EMSD guideline of about 75 pages: scope of the energy audit, central services boundary for data-centre portions of industrial buildings, a 5-year audit interval and EAC 2024 requirements…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
The Green Grid, 2024, Guide or technical publication
The Green Grid's spreadsheet tool, posted 24 January 2024, compares total cost of ownership of air and liquid cooling architectures; version 4.1 adds a workload-dependent liquid cooling efficiency…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
The Green Grid, 2024, Guide or technical publication
The Green Grid's SEED v2.0 spreadsheet, dated 28 June 2024, holds anonymised server energy-efficiency data collected from multiple equipment manufacturers and is updated as new data arrive.
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
State of Victoria, Department of Jobs, Skills, Industry and Regions, 2026, Guide or technical publication
Victoria's 2026 action plan coordinates land, grid, water and local-benefit expectations for data centres: operational electricity should be offset by new renewable supply and storage, and water-inte…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Türk Tesisat Mühendisleri Derneği, 2026, Guide or technical publication
The 132-page 2026 TTMD proceedings include two data centre papers: PCNN reconstruction of temperature fields from sparse sensors (mean absolute error 0.75 degrees C, about 1 ms inference) and a guide…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
Enerji ve Tabii Kaynaklar Bakanlığı / EVÇED, 2025, Guide or technical publication
The Turkish Ministry of Energy and Natural Resources form for the 2023 calculation period gives a national generation emission factor of 0.430 tCO2/MWh and 0.433 tCO2/MWh for transmission-connected…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Enerji ve Tabii Kaynaklar Bakanlığı / EVÇED, 2025, Guide or technical publication
The Turkish Ministry of Energy and Natural Resources form for 2023 gives grid emission factors by the UNFCCC CDM Tool 07 method: operating margin 0.7134 and build margin 0.3567 tCO2/MWh.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
UK Government (GOV.UK), 2025, Guide or technical publication
UK policy paper (July 2025) setting the national plan for AI compute and data-centre infrastructure.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
ENERGY STAR, 2019, Guide or technical publication
The ENERGY STAR page summarising UPS Version 2.0 for AC-output units operating in a single input dependency: the load-weighted average efficiency formula, loading assumptions, minimum efficiency equa…
Guide or technical publication
2019
Read at publisher (opens in a new tab)↗
North American Electric Reliability Corporation (NERC), 2025, Guide or technical publication
The first white paper of NERC's Large Loads Task Force; it defines large loads such as data centres, crypto mining and hydrogen production, characterises their electrical behaviour and ranks the risk…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗