Store CDU capacity in the catalogue using this rating basis (kW at 5 C ATD, 1.5 LPM/kW, head and FWS impedance) so units from different vendors can be compared, and derate when the design ATD or flow differs.
In-row CDU rating: as in-rack, but TCS head at least 40 psi at X x 1.5 LPM.
In AI data-centre carbon estimation, compute operational (FLOPs, power, PUE, grid intensity) and embodied (chip area × CPA, memory and storage per GB) carbon together; in a renewable-powered facility embodied carbon rises to 92-95%.
Against published Google and Meta figures, error is 8.2% or less for training and -3.05% for embodied carbon.
In data-centre carbon accounting, consider hourly locational marginal emissions (LME) rather than an annual-average grid factor; the LME-based intensity (about 672 kgCO2/MWh) was about 3 times the average factor (202).
Emission rates assumed in the simulated grid: coal 800 kgCO2/MWh, gas 450 kgCO2/MWh, wind/solar/nuclear/hydro 0.
In a fault-loop checker, compute fault-loop impedance for each final and distribution circuit and verify automatic disconnection times for the chosen earthing system.
In a commissioning module, generate an initial-verification test schedule per circuit from the design model: continuity, insulation resistance, polarity, fault-loop impedance and RCD tests.
In surge and EMC design, add an SPD placement rule set: origin of the installation, sub-distribution and sensitive IT boards, with DC SPDs for battery and PV DC buses.
In the switchboard catalogue, store the assembly's rated current (InA), the group rated current or rated diversity factor per circuit, Icw/Ipk and the form of separation.
Related documents: IEC 61439-2, IEC 61439-6, EN 61439-1, TS EN 61439-1.
On the main LV switchboard object, require form of separation (1-4b) as a catalogue field and default to Form 3b/4 for concurrently maintainable designs.