745–768 / 1044

White paperFree to read

Eaton 2018

What You Need to Know About Arc Flash

Add arc-flash attributes per switchboard (available fault current, clearing time, maintenance-mode/ZSI availability, working distance) and compute incident energy per IEEE 1584 for line and load side.

  • NFPA 70E 130.5(G): the incident energy analysis must be updated at least every 5 years.
White paperPDF

Open Compute Project Foundation 2022

White Paper: OCP Ready Data Centers - Program Mission, Methodology, and Case Studies, Revision 1.0 (June 2022)

Offer an 'OCP Ready' compliance profile that checks the delivery path (dock, ramps, door heights), floor load classes (uniform, concentrated, rolling), 3-phase IEC/NEMA rack circuits, hot/cold-aisle containment and generator load-acceptance time relative to BBU autonomy.

  • Design PUE ranges from 1.07 (Hydro66, WUE 0.059 L/kWh) to 1.6 (maincubes AMS01).
White paperFree to read

Rittal 2017

Whitepaper Rittal Liquid Cooling Packages

Catalogue close-coupled coolers by type (inline row, closed-loop rack, rear door, DX rack), rated kW, width, footprint, maximum air delta-T and water/refrigerant inlet temperatures.

  • Hybrid doors come in 10 kW and 20 kW versions and open 130 degrees.
White paperFree to read

Rittal 2014

Whitepaper Rittal PDU international

Keep PDU catalogue fields for phases, input A, max kW, outlet types, ambient rating, metering accuracy, relay type and management protocol (SNMPv3).

  • C14 inlets carry up to 10 A; C20 up to 16 A for large consumers.
Research paperPDF

arXiv preprint (University of Texas at Austin; formatted for IEEE Transactions on Power Systems) 2025

Wide-Area Power System Oscillations from Large-Scale AI Workloads

Model AI data-centre load as a persistent periodic forcing (0.3-1.5 Hz band, about 20% of peak fluctuating) rather than a ramp, and add oscillation analysis to the grid-interconnection study.

  • The fine-tuning model uses a dominant frequency U(0.3, 0.7) Hz and compute fraction 0.7-0.9.