IEA 4E EDNA, 2025, Guide or technical publication
The April 2025 IEA 4E EDNA study examines how server efficiency developed over the past decade: compound annual growth of 26% for general-purpose servers, 49% for accelerated computing chips and 47%…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
BMWK / BAFA, 2024, Guide or technical publication
The German Federal Ministry for Economic Affairs and BAFA FAQ of 11 June 2024 interprets EnEfG data-centre duties: reporting by 31 March, a management system by 1 July 2025, and certification from 1…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Korea Data Center Council (KDCC), Year not stated, Guide or technical publication
The Korea Data Center Council's voluntary Green Data Centre certification scores Version 5 as 60 of 100 points for PUE and 40 for green activities, with four grades from Bronze to Platinum.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Malaysian Investment Development Authority, Year not stated, Guide or technical publication
Malaysia's MIDA guideline ties the DESAC tax incentive to declared design PUE, CUE and WUE: PUE of 1.4 or below for hyperscale, 1.6 to 1.7 or below for colocation, and WUE of 2.2 m3/MWh or lower.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, Year not stated, Guide or technical publication
A standard-operating-procedure primer from Microsoft and WSP on running cradle-to-grave life cycle assessments of servers and whole data centres. It is useful background for embodied-carbon modules…
Guide or technical publication
-
PDF
Korean Green Management Information Portal (GMI), Year not stated, Guide or technical publication
The Korean K-Taxonomy commentary recognises low-carbon data centres by green data-centre certification, or by building certification plus PUE below 1.4 (new) or 1.5 (existing).
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
Climate Neutral Data Centre Pact (CNDCP), 2025, Guide or technical publication
A 17-page 2025 paper from the Climate Neutral Data Centre Pact arguing that EU minimum performance standards for data centres are premature, and that a PUE floor should sit near 1.8-1.9.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
NABERS, Year not stated, Guide or technical publication
The NABERS programme separates measured operational ratings from commitments for new projects and offers two energy rating types: Infrastructure and Whole facility.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
NABERS, 2024, Guide or technical publication
NABERS's April 2024 rules version 2.0 define the operational rating for Australian data centres; they supersede the 2014 v1.1 rules and distinguish Infrastructure, IT equipment and Whole facility…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Netherlands Enterprise Agency (RVO), Year not stated, Guide or technical publication
Dutch RVO guidance: data centres with at least 500 kW installed IT power report their energy efficiency every year (16 March to 15 May in 2026); 36% of EU data centres, or 770 sites, took part.
Guide or technical publication
-
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2015, Guide or technical publication
ITU-T L.1301 (2015) defines the minimum static and dynamic data set to collect from ICT and facility equipment for data-centre energy management; suggested power measurement accuracy is ±2%.
Guide or technical publication
2015
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2015, Guide or technical publication
ITU-T L.1302 (2015) gives the method for calculating an operating data centre's PUE, pPUE, power-feeding efficiency and cooling CLF, using a 12-month assessment, measurement at least every 30 minutes…
Guide or technical publication
2015
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2024, Guide or technical publication
ITU-T L.1307 (March 2024) defines design requirements for micro data centres and an indicator, EEI(MDC) = ITEUsv / PUE, that relates server CPU utilisation to PUE; it recommends 5-10 minutes of UPS…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2025, Guide or technical publication
ITU-T Recommendation L.1308 (December 2025) advises new low-carbon data centres to target an annual PUE of 1.3 in cool and 1.4 in warm climates, with a 75% renewable energy factor.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2014, Guide or technical publication
ITU-T L.1320 (2014) defines efficiency formulas, test conditions and measurement setups for UPS, inverters, rectifiers, DC/DC converters, renewable sources and cooling equipment.
Guide or technical publication
2014
Read at publisher (opens in a new tab)↗
International Telecommunication Union (ITU-T), 2025, Guide or technical publication
ITU-T L.1322 (December 2025) defines a standard framework that evaluates data centre thermal performance at room, row, cabinet, device and chip level using indicators such as SHI; its appendix exampl…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
PUB, Singapore’s National Water Agency, 2025, Guide or technical publication
A December 2025 page from Singapore's national water agency PUB publishing a data-centre median water efficiency index of 2.1 m³/MWh, derived from mandatory large-user submissions.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Electrical and Mechanical Services Department, Hong Kong, 2026, Guide or technical publication
Hong Kong EMSD guideline of about 75 pages: scope of the energy audit, central services boundary for data-centre portions of industrial buildings, a 5-year audit interval and EAC 2024 requirements…
Guide or technical publication
2026
Read at publisher (opens in a new tab)↗
The Green Grid, 2024, Guide or technical publication
The Green Grid's spreadsheet tool, posted 24 January 2024, compares total cost of ownership of air and liquid cooling architectures; version 4.1 adds a workload-dependent liquid cooling efficiency…
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
The Green Grid, 2024, Guide or technical publication
The Green Grid's SEED v2.0 spreadsheet, dated 28 June 2024, holds anonymised server energy-efficiency data collected from multiple equipment manufacturers and is updated as new data arrive.
Guide or technical publication
2024
Read at publisher (opens in a new tab)↗
Enerji ve Tabii Kaynaklar Bakanlığı / EVÇED, 2025, Guide or technical publication
The Turkish Ministry of Energy and Natural Resources form for the 2023 calculation period gives a national generation emission factor of 0.430 tCO2/MWh and 0.433 tCO2/MWh for transmission-connected…
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Enerji ve Tabii Kaynaklar Bakanlığı / EVÇED, 2025, Guide or technical publication
The Turkish Ministry of Energy and Natural Resources form for 2023 gives grid emission factors by the UNFCCC CDM Tool 07 method: operating margin 0.7134 and build margin 0.3567 tCO2/MWh.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗
Open Compute Project Foundation, Year not stated, Guide or technical publication
Sets out how OCP's Sustainability Project (made OCP's fifth tenet after the 2022 Global Summit) defines sustainability: transparency and reporting, circularity and efficiency. For operators it explai…
Guide or technical publication
-
PDF
Taiwan Ministry of Economic Affairs, 2025, Guide or technical publication
Official amendment adds a data-processing and hosting best-available-techniques annex covering IT choices, cooling, power and energy monitoring.
Guide or technical publication
2025
Read at publisher (opens in a new tab)↗