Offer a W-class selector for liquid-cooled systems that sets supply-temperature ranges and links to whether chillers, dry coolers or towers are needed.
ASHRAE defines liquid-cooling classes W1 to W5 for facility water temperature, each with a typical infrastructure scheme.
In the commissioning module, include a TAB task list per cooling unit and hydronic circuit (design versus measured airflow, water flow, differential pressure, set points).
The reported outcome is a 10-25% energy efficiency improvement.
For customers who self-host SoSo CAD, generate a VERBİS-ready inventory (purposes, data categories, recipients, foreign transfers, security measures) from the product's data-processing configuration.
For legal persons the controller is the legal entity itself (Article 11).
Default liquid-cooled designs to warm facility water (W40/W45) in chiller-free or dry-cooler-only plant options, citing this paper as supporting evidence.
The volumetric heat transfer ratio of water to air is cited as about 1900:1.
Add arc-flash attributes per switchboard (available fault current, clearing time, maintenance-mode/ZSI availability, working distance) and compute incident energy per IEEE 1584 for line and load side.
NFPA 70E 130.5(G): the incident energy analysis must be updated at least every 5 years.
Model cooler redundancy explicitly: 2N may come from two units or one unit with dual independent power and water feeds, so catalogue entries need an 'internal redundancy' field.
Close-coupled units keep all 42U of a 2000 mm enclosure free for IT.
Offer an 'OCP Ready' compliance profile that checks the delivery path (dock, ramps, door heights), floor load classes (uniform, concentrated, rolling), 3-phase IEC/NEMA rack circuits, hot/cold-aisle containment and generator load-acceptance time relative to BBU autonomy.
Design PUE ranges from 1.07 (Hydro66, WUE 0.059 L/kWh) to 1.6 (maincubes AMS01).
In the free-cooling estimator compute economiser hours from hourly climate data against the required water supply temperature and report the percentage of the year.
Battery life benefits from about 20 C storage temperature.
Catalogue close-coupled coolers by type (inline row, closed-loop rack, rear door, DX rack), rated kW, width, footprint, maximum air delta-T and water/refrigerant inlet temperatures.
Hybrid doors come in 10 kW and 20 kW versions and open 130 degrees.
In a portfolio/edge module let users model multiple sites with availability (or tier), headcount served and severity (1-5), compute series availability for dependent sites and rank sites by downtime x severity.
Scorecard: annual downtime hours x severity (1-5), an FMECA-style ranking.