Collection

Recently added

Technical references added to the library in the last 90 days.

Sources
1044
Downloadable PDFs
270
Years
1984–2027

All sources

49–72 / 1044

White paperFree to read

Schneider Electric 2011

AC vs. DC Power Distribution for Data Centers

In the power-chain efficiency calculator multiply UPS, transformer/PDU, distribution and PSU efficiencies at the actual load fraction rather than nameplate, and offer architecture presets for the five options with Table 1 values as defaults.

  • The paper calls the North American 480 V AC system with PDU transformers inefficient and obsolete for new designs.
Research paperPDF

Technology Review for Carbon Neutrality (Tsinghua University Press) 2025

Accelerating liquid cooling adoption in data centers: necessity, challenges and solutions

For racks where GPU/accelerator thermal design power exceeds 1,200 W, take liquid cooling as a mandatory design input, and weigh the initial cost (about 1.9-2.2 times air cooling) against TCO (up to 20% lower after 4 years, vendor figure).

  • Cooling systems in air-cooled data centres consume around 40% of total data-centre energy.
Research paperPDF

Applied Energy (Elsevier BV) 2025

Accounting carbon emissions from electricity generation: a review and comparison of emission factor-based methods

In data-centre carbon accounting, state the method (Tier 1, 2, 3) and factor source (IPCC or national) when choosing a grid emission factor; simple methods can underestimate generation emissions by about 73%.

  • AEF for the North zone by Method 5 rose from 0.1627 tCO2/MWh in 2016 to 0.4709 in 2022, then fell to 0.3936 in 2023.
Research paperFree to read

arXiv preprint (Cadence Design Systems) 2026

AI-driven Thermal-aware Data Center Capacity Planning

For layout iteration and add-load what-ifs, a surrogate that predicts only cabinet-inlet temperature (the compliance quantity) is cheaper and more accurate than full-field surrogates.

  • As a practical guideline, an initial dataset is about 500 simulation cases with around ten randomised parameters.
White paperFree to read

Schneider Electric 2021

An Overview of Cybersecurity Best Practices for Edge Computing

Give every network-managed infrastructure device (UPS card, rack PDU, CRAC/CRAH controller, BMS gateway, sensor) catalogue fields for TLS support, RBAC support, IEC 62443-4-2 certification (SL level) and SDL certification.

  • IEC 62443 has four parts; 4-1 covers secure product development and 4-2 the technical security requirements for components.
Research paperPDF

Energies (MDPI AG) 2018

Analysis of Air-Side Economizers in Terms of Cooling-Energy Performance in a Data Center Considering Exhaust Air Recirculation

In airside economiser design, plan exhaust grilles and the building envelope so recirculation stays below 5%; 15% recirculation raised energy about 6.1% for direct and 9% for indirect.

  • The authors recommend placing exhaust-air grilles so recirculation is below 5%, or handling it in the envelope plan at design stage.